Connecting the Sensor Head
This section describes how to connect the Amplifier Unit.
• Before connecting/disconnecting the Sensor Head, make sure that the Amplifier Unit is turned OFF.
The Smart Sensor may break down if the Sensor Head is connected or disconnected while the power
is ON.
• Do not touch the terminals inside the connector.
■ Connecting the Sensor Head
Insert the Sensor Head connector into the Sensor Head connector of the Amplifier Unit.
Attach the ferrite cores on the cable of the Sensor Head.
Make sure that one ferrite core is attached to the connector side as well as to the body side.
■ Disconnecting the Sensor Head
Pull out the Sensor Head connector while pressing the hooks on both sides of the Sen-
sor Head connector.
Ferrite core
Section 2
Sensor Head
ZFV-C
51
User's Manual