Troubleshooting - Omron ZFV-C User Manual

Smart sensors with ultra-high-speed color ccd cameras
Hide thumbs Also See for ZFV-C:
Table of Contents

Advertisement

Section 6

Troubleshooting

Troubleshooting

This section describes countermeasures for temporary hardware problems. Check the
malfunction in this section before sending the hardware for repair.
Problem
OUTPUT indicator does not lit.
RUN indicator does not lit.
Dark LCD screen
Images are not displayed.
Screen is not displayed when
amplifier units are gang-
mounted.
Measurement results are not dis-
played.
The TRIG signal (input signal) is
not accepted.
The OUTPUT signal is not out-
put.
The ENABLE signal does not
turn ON.
The bank is not switched even if
the bank switching signal is input
from the outside.
No communications with per-
sonal computer.
ZFV-C
120
User's Manual
Probable cause and possible countermeasure
• Check the setting of [SYS2]-[OUTPUT]-[ONSTATUS].
To lit the indicator (OUTPUT signal ON) when the judgment is OK,
select [OK ON], and to lit the indicator (OUTPUT signal ON) when
the judgment is NG, select [NG ON].
• Is the operating mode switch set to "RUN"?
• Is the "Eco" mode function set?
The "Eco" mode is set if pressing any key automatically returns to
the original brightness.
The brightness is maintained when the "Eco" mode setting is can-
celed. Note, however, that the life of the LCD backlight is short-
ened. So, we recommend setting the "Eco" mode.
• Is the Sensor Head connector connected correctly?
• Is the brightness of the LED light set to a dark value?
• Is power turned ON to all the gang-mounted amplifier units simul-
taneously?
• Is the operating mode switch set to "RUN"?
• Are all cables connected correctly?
• Is the signal line disconnected?
• Is the operating mode switch set to "RUN"?
• Is the TRIG signal being input?
• Are all cables connected correctly?
• Is the signal line disconnected?
• Is the operating mode switch set to "RUN"?
• Is the operating mode switch set to "RUN"?
• Is the bank switching method set to [I/O]?
When the bank switching method is set to [KEY], the external
inputs of the BANK 1 to 3 are not accepted.
• Is the operating mode switch set to "RUN"?
• Is the USB cable is connected correctly.
• Is the RS-232C cable connected correctly?
• Are any other applications using the port on the personal com-
puter?
• Are the same communication conditions are set to both personal
computer and Amplifier Unit?
• Has the USB driver been installed?
• Is the Amplifier Unit operating correctly?
Page
p.109
p.27
p.100
p.51
p.94
p.21
p.27
p.39
p.27
p.39
p.27
p.27
p.97
p.27
p.104