Section 4
Inspecting by Pattern (PATTERN)

Basic Setting Procedure

■ Teaching
The area to be inspected needs to be enclosed by a rectangular box, then teach it. The
selected image in the area is registered as the inspection reference (model).
Measurement is unstable when there are two or more of the same pattern. Register
unique pattern in the screen or restrict the search range.
Application and Setting Examples p.152
■ Adjusting the threshold level
Threshold values are adjusted to determine the range for OK judgment. Adjust the
threshold values referring to the current indicated measurement results. Adjustment of
the threshold values must be done in ADJ mode.
● Switching to ADJ mode
ADJ
MENU
RUN
Setting item
Correlation
value
Area value
ZFV-C
64
User's Manual
Inspection area
Teaching
setting
SEARCH
OK
ABCDE
● Adjustment of correlation
value
SEARCH
ABCDE
TH
[
60]
Range
0 to 100
This is the lower limit of the correlation value with the teaching model. This
value or above is judged as OK.
0 to 999
Displayed when [COL JUGE] - [ON] is selected in the CUSTOM menu. "Area
of the largest color group" is registered as the reference area when teaching
is performed. Set the range for OK judgment with the registered area as
"100".
● Adjustment of area value
OK
Measured
80
values
Correlation value
Upper/lower limit
LEFT/RIGHT keys: Select upper limit/lower limit.
UP/DOWN keys:
Details of Adjustment
SEARCH
OK
ABCDE
Measured
80
values
L: [ 80] H:[ 120] B
Lower limit
Upper limit
Change values.