Section 2
Amplifier Unit

Gang-Mounting

The following describes how to gang-mount Amplifier Units.
■ Mounting on a DIN track
1.
Install a Amplifier Unit on a DIN track.
2.
Open the connector cover of each Ampli-
fier Unit.
Slide the cover to remove.
3.
Insert the Controller Link Unit into the
connector on the one of Amplifier Units.
4.
Slide the other Amplifier Unit, and insert
into the connector on the Controller Link Unit.
■ Removal procedure
1.
Slide one of Amplifier Units, and remove
it from the connector on the Controller
Link Unit.
2.
Slide the Controller Link Unit and
remove it from the connector on the
Amplifier Unit.
3.
Put the cover on the connector of the
Amplifier Unit.
4.
Pull the hook on the I/O cable end down-
wards.
5.
Lift up the Amplifier Unit from the I/O
cable end, and remove it from the DIN
track.
ZFV-C
36
User's Manual
p.33
Controller
Link Unit
Controller
Link Unit
Hook on I/O cable
end