Control Change Table - Physis Piano K4 User Manual

Sound expandable midi/usb controller
Table of Contents

Advertisement

 

CONTROL CHANGE TABLE

Virtual Instruments also allow Control Change tables, containing names assigned to Control Change messages, so as to
recognize the parameters of external devices through proper names.
To do so, press [F3] or move the cursor to the left. The following page will appear:
the following parameters are available:
Table Enable: enable (YES) or disable (NO) the Control Change table; when enabled, the assigned names appear on
the Message MSB – LSB column of the control pages.
Control Name: name of controls/parameters of the external device. Control Change numbers used by the receiving
instruments appear in this table. Read the user manual of the device to see what name is assigned to each Control
Change, then enter the names in the table following the procedure:
1.
press [ ] to place the cursor on the table,
2.
use the arrow buttons [ ] and [ ] to scroll the table and place the cursor on the desired Control Change. The
same buttons used with the [SHIFT] button allow you to skip ten steps.
3.
press [ENTER] and enter the name, following the procedure described at chapter 5.2.
Press the function buttons [F1], [F2], [F3] and [F4] to access the other video pages of the INSTRUMENTS section.
To return to SYSTEM MODE, press [EXIT].
To return to PERFORMANCE MODE, press [SYSTEM] or [EXIT] two times.
Press a MODE button to access the corresponding operating mode.
NRPN TABLE
In addition to Control Changes, a Virtual Instrument can also associate names to NRPN messages, so as to make them
more easily recognizable while setting parameters.
Press [F4] or move the cursor to the left. The following page will appear:
Available parameters are:
Table Enable: enable (YES) or disable (NO) the NRPN table. When enabled, the assigned names appear under the
Message MSB – LSB column of the control pages.
MSB LSN NRPN Name: names of the controls/parameters available in the external device. The number on the list are
the two NRPN MSB and LSB messages that the receiving instrument uses to adjust controls. Read the user manual of
the device to see what name is assigned to each Control Change, then enter the names in the table following the
procedure:
1.
Press the [ ] button to place the cursor on the table,
2.
use the arrow buttons [ ], [ ], [ ] and [ ] to select the MSN and LSB values and define their NRPN. You can
also use the [ ] and [ ] with [SHIFT] key to jump 10 positions.
User Manual – General instrument settings (System Mode)
EN - 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K5 exK4 gw

Table of Contents