User Manual of VCA Network Speed Dome
Appendix 7 Alarm In/Out Connections
This section is only for the speed domes with alarm in/out functions.
The speed dome can be connected with alarm inputs (0~5VDC) and alarm outputs.
Refer to the following diagrams for alarm output:
DC Load
OUT(n)
Dome
+
-
DC
Relay Output
OUT(n)
Diagram (left)
The alarm provides the relay output (no voltage), and the external power supply is
required when it connects to the alarm device.
For DC power supply (left diagram), the input voltage must be no more than
30VDC, 1A.
For AC power supply, the external relay must be used (right diagram) to prevent
damages to the speed dome and avoid risk of electric shock.
© Hikvision
OUT(n)
Dome
Relay Output
OUT(n)
Figure A-11 Alarm Out Connections
JQC- 3FG
GND OUT
Relay
(10 A 250VAC)
30VDC
1A
Diagram(right)
130
~220V AC
L