HIKVISION IR Speed Dome Installation Manual
HIKVISION IR Speed Dome Installation Manual

HIKVISION IR Speed Dome Installation Manual

Hikvision ir speed dome installation manual
Hide thumbs Also See for IR Speed Dome:

Advertisement

IR Speed Dome
Installation Manual
V2.0.1

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION IR Speed Dome

  • Page 1 IR Speed Dome Installation Manual V2.0.1...
  • Page 2 LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, AND THE LIKE) ARISING OUT OF THE USE OR INABILITY TO USE THE HIKVISION SOFTWARE EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
  • Page 3: Regulatory Information

    IR Speed Dome Installation Manual Regulatory Information FCC Information compliance: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4: Safety Warnings And Cautions

    IR Speed Dome Installation Manual Safety Warnings and Cautions Please pay attention to the following warnings and cautions: Hazardous Voltage may be present: Special measures and precautions must be taken when using this device. Some potentials (voltages) on the device may present a hazard to the user. This device should only be used by employees from our company with knowledge and training in working with these types of devices that contain live circuits.
  • Page 5 IR Speed Dome Installation Manual in your region. It must have certification marks showing certification by an agency in your region. The connector that plugs into the AC receptacle on the power supply must be an IEC 320, sheet C13, female connector. See the following website for more information http://kropla.com/electric2.htm.
  • Page 6 IR Speed Dome Installation Manual Preventive and Cautionary Tips Before connecting and operating this product, please be advised of the following tips: • All the operations should strictly comply with the local electrical safety regulations, fire prevention regulations and other related regulations.
  • Page 7: Table Of Contents

    IR Speed Dome Installation Manual Table of Contents Chapter 1 Installation and Settings ..........................5 1.1 Installation ..............................5 1.2 Cabling ................................8 1.2.1 Cable Standards ..........................8 1.2.2 Cabling Instructions ..........................9 1.2.3 Alarm Input /Output .......................... 12 1.3 DIP Switch Settings ............................. 12 1.3.1 Address Settings ..........................
  • Page 8: Chapter 1 Installation And Settings

    IR Speed Dome Installation Manual Chapter 1 Installation and Settings The following installation instructions are applicable to Hikvision IR speed domes, network IR speed domes and network high-definition IR speed domes. Wall mounting is chosen as an example in this chapter.
  • Page 9 IR Speed Dome Installation Manual Figure1. 2 Fasten the fast-mounting Adapter 3. Loosen both of the lock screws on the fast-mounting adapter, screw the top cover to the adapter and fasten the lock screws with the L-shaped wrench. Figure1. 3 Install the Top Cover Figure1.
  • Page 10 IR Speed Dome Installation Manual Protective Sticker Network High-definition IR Speed Dome (Network) IR Speed Dome Figure1. 5 Tear off the Protective Stickers 5. Install the sealing loop or waterproofing and tie the safety lanyard to the dome. Network High-definition IR Speed Dome (network) IR Speed Dome Figure1.
  • Page 11: Cabling

    Figure1. 8 Hang the Dome to the Top Cover 7. Fasten the set screws to reinforce the mounting Network High-definition IR Speed Dome (Network) IR Speed Dome Figure1. 9 Fix the IR Speed Dome 1.2 Cabling Note: Please turn off the power before cabling.
  • Page 12: Cabling Instructions

    (mm²)) of the dome. For IR speed dome, L (m) = 50 * S; while for network IR speed domes, L (m) =40 * S. For example, if the cross-sectional area of bare cable is 1mm ², the transmission distance of IR speed dome and network IR speed dome should not exceed 50m and 40m respectively.
  • Page 13 IR Speed Dome Installation Manual Figure1. 11 Network Speed Dome Integrated Cables Take alarm input/output cabling for IR speed dome as an example: Steps: 6. Open the head cover of the dome and find the alarm in/out terminals on the bottom circuit board as shown in Figure1.12.
  • Page 14 IR Speed Dome Installation Manual Figure1. 12 Bottom Circuit Board of IR Speed Dome Figure1. 13 Bottom Circuit Board of Network IR Speed Dome...
  • Page 15: Alarm Input /Output

    Bottom Circuit Board of Network High-definition IR Speed Dome) 1.2.3 Alarm Input /Output Both the IR speed dome and network IR speed dome models support up to 7 alarm inputs (0~12VDC), 2 alarm outputs and relay output (no voltage). JQC- 3FG...
  • Page 16: Address Settings

    IR Speed Dome Installation Manual Note: 1. 485 serial port parameters of network high-definition IR speed dome should be configured in OSD menu. You can login to client software or open IE browser and navigate to “Remote Settings” to configure.
  • Page 17 IR Speed Dome Installation Manual Dome Address SW1 Settings OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON Table 1.1 Address Settings For addresses 0-71, please refer to Table 1.2:...
  • Page 18 IR Speed Dome Installation Manual Table 1.2 Address Settings...
  • Page 19: Baud Rate Settings

    Note: 1. Network speed domes does not support Manchester code protocol. 2. IR speed dome is self-adaptive to PELCO-D, PELCO-P, HIK-Code, VICON and KALATEL-32 protocols, and network IR speed dome is self-adaptive to PELCO-P, PELCO-D and HIK-Code protocols. Protocol settings are not applicable for both.
  • Page 20: Terminal Resistor Connection Settings

    IR Speed Dome Installation Manual Types Position 7 Settings Simplex Half-duplex Table 1.5 Communication Type Settings 1.3.5 Terminal Resistor Connection Settings Position 8 of SW2 is used for terminal matched resistor settings DIP Switch SW2-Terminal Resistor Connection Settings State Position 8 Setting...
  • Page 21: Chapter 2 Mount Selection

    IR Speed Dome Installation Manual Chapter 2 Mount Selection 2.1 Long Wall Mount Figure2. 1 Long Wall Mount Figure2. 1 Long Wall Mount Dimensions...
  • Page 22: Short Wall Mount

    IR Speed Dome Installation Manual Figure2. 2 Wall Mount with Power Supply Box 2.2 Short Wall Mount Figure2. 3 Short Wall Mount Figure2. 4 Short Wall Mount Dimensions...
  • Page 23: Corner Mount

    IR Speed Dome Installation Manual 2.3 Corner Mount Figure2. 6 Corner Mount 2.4 Pole Mount Figure2. 7 Pole Mount...
  • Page 24: Chapter 3 Mounting Instructions

    IR Speed Dome Installation Manual Chapter 3 Mounting Instructions Before you start: For cement walls, expansion screws are needed for mounting (mounting in cement walls are taken as examples in blow sections). For wooden walls, you need to use self-tapping screws. Please make sure that the wall is sturdy enough to withstand more than 3 times the weight of the dome and the bracket.
  • Page 25: Mounting With A Long Mount

    IR Speed Dome Installation Manual 3.1.2 Mounting with a Long Mount Steps: 1. Drill four holes in the wall, insert M6 expansion screws (not supplied) into the mounting holes. Figure3. 3 Drill the Holes in the Cement Wall 2. Screw hex nuts padded with flat washers through the wall mount and the rubber gaskets with the expansion screws to secure the mount.
  • Page 26: Mounting With A Power Supply Box

    IR Speed Dome Installation Manual 3.1.3 Mounting with a Power Supply Box Steps: 1. Drill four holes in the wall, insert M10 expansion screws (not supplied) into the mounting holes. 2. Secure the power supply box to the wall with nuts and washers. Tighten the four expansion screws.
  • Page 27: Corner Mounting

    IR Speed Dome Installation Manual 3.2 Corner Mounting Note: Corner mounting is applicable to indoor/outdoor 90°corner constructions. 3.2.1 Components 1. Mounts A corner mount has to be used together with a wall mount for corner mounting applications. Figure3. 7 Corner Mount Figure3.
  • Page 28: Corner Mounting Instructions

    IR Speed Dome Installation Manual 3.2.2 Corner Mounting Instructions Steps: 1. Drill four holes in the corner, insert M6 expansion screws (not supplied) into the holes, and position the mount to the wall. 2. Pass the power cord, video cable and control line through the opening of the corner mount.
  • Page 29: Pole Mounting Applications

    IR Speed Dome Installation Manual Figure3. 11 Install the Wall Mount 5. Install the dome to the mount Please refer to Chapter 1 for dome installation. 3.3 Pole Mounting Applications Note: Pole mounting is applicable to the indoor/outdoor pole constructions 3.3.1 Mounting Components...
  • Page 30 IR Speed Dome Installation Manual Figure3. 13 Wall Mount 2. Pole Mounting Hoop Pole mounting hoop is used for pole mounting with pole mount and wall mount. There are following dimensions selectable: φ59-82mm, φ84-108mm, φ103-127mm, φ130-152mm, φ155-178mm, φ180-203mm and φ194-216mm. Dimensions can be customized according to users’...
  • Page 31: Pole Mounting Instructions

    IR Speed Dome Installation Manual Figure3. 15 Hexagonal Screws (M8×30) and Spring Washers 3.3.2 Pole Mounting Instructions Steps: 1. To assemble pole mount and pole mounting hoops, loosen the hoops with a screw driver and insert them through the holes of the mount.
  • Page 32 IR Speed Dome Installation Manual Figure3. 17 Install the Pole Mount 5. Position the wall mount, fasten the hexagonal screws with the spring washers through the wall mount and the gaskets, and tighten them with the pole mount. Figure3. 18 Install the Wall Mount 6.
  • Page 33: Appendix 1 Lightning And Power Surge Protection

    IR Speed Dome Installation Manual Appendix 1 Lightning and Power Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W (Eg, Lightning , power surges and etc.) Necessary protections must be taken to secure the electrical safety outdoors.
  • Page 34 IR Speed Dome Installation Manual Figure4. 1 Lightning Protection and Grounding...
  • Page 35: Appendix 2 Rs485 Bus Connection

    IR Speed Dome Installation Manual Appendix 2 RS485 Bus Connection 1. RS485 Bus Properties RS485 is a half-duplex communication bus which has 120Ω characteristic impedance, and its maximum load ability is 32 payloads (including controlling devices and controlled devices). 2. RS485 Bus Transmission Distance Using 0.56mm (24AWG) twisted-pair line, the max transmission distances for different baud rates...
  • Page 36 IR Speed Dome Installation Manual Figure4. 3 Simplified Connection 4. Terminal Resistor Connection The 120Ω terminal resistors can be connected through the DIP switch on the circuit board and default as disconnected. To connect the resistor, simply switch on the eighth position of SW2. Please refer to section 1.3 for more about DIP switch settings.
  • Page 37 IR Speed Dome Installation Manual Figure4. 5 RS485 Distributer Figure 5 6. FAQ about RS485 Bus Table 4.2 RS485 Bus FAQs and Solutions...
  • Page 38: Appendix 3 Wire Gauge Standards

    IR Speed Dome Installation Manual Appendix 3 Wire Gauge Standards Table 4.3 Wire Gauge Standards...

Table of Contents