Thermostat Refitting - Gilera SMT RCR 633793 Service Station Manual

Table of Contents

Advertisement

SMT RCR
Characteristic
Activation
124 ± 3°C
Deactivation
114 ± 3°C
Thermostat check
Measuring the valve opening temperature:
- Immerse the thermostat and the thermometer in
hot water.
Neither of them should get into contact with the
container walls or bottom; otherwise, the reading
will not be accurate.
1 - Thermometer
2 - Thermostat (the thermostat must be totally im-
mersed into the water)
- Replace the thermostat if the results do not fall
within the specification values.
Characteristic
Valve opening at 67±3 °C :
0.1 mm
Valve opening at 75°C :
3 mm
Refitting
- Fit the thermoswitch (3)
- Connect the connector (2) to the thermoswitch
- Fit the thermostat and its fixing screw (1)
- Connect the sleeve to the cylinder head
- Fill up the cooling system with the recommended
coolant
Cooling system
COOL SYS - 105