Wexiodisk WD-7 DUPLUS Installation And User Manual page 26

Hood type dishwasher
Hide thumbs Also See for WD-7 DUPLUS:
Table of Contents

Advertisement

Installation
Relay 11/J73. Dead closing function
(230V/400V 3-phase machine)
To use the closing function without a power supply, follow these instructions:
Contact the equipment to be controlled to contacts J73-103 and J73-104.
Relay 11/J73. 230V AC version (400V 3-phase machine)
To connect a 230V AC power supply to the contact, follow these instructions:
If a 230V AC version of J71 is fitted:
Connect J71-105 to J73-104 using a black 0.75mm² wire.
If J71 is not fitted or is not a 230V AC version:
Connect a black 0.75mm² wire from connector X10 to contact J73-104.
Connect the equipment to be controlled between contact J73-103 and con-
nector N1, N2 or N3 in the electrical cabinet.
Relay 11/J73. 230V AC version (230V 3-phase machine)
To connect a 230V AC power supply to the contact, follow these instructions:
If a 230V AC version of J71 is fitted:
Connect J71-105 to J73-104 using a black 0.75mm² wire.
If J71 is not fitted or is not a 230V AC version:
Connect a black 0.75mm² wire from connector X10 to contact J73-104.
Connect the equipment to be controlled between contact J73-103 and con-
nector X10 in the electrical cabinet.
Relay 11/J73. Relay 11. 24V AC version
(230V/400V 3-phase machine)
To connect a 24V AC power supply to the contact, follow these instructions:
If a 24V AC version of J71 is fitted:
Connect J71-105 to J73-104 using a red 0.75mm² wire.
If J71 is not fitted or is not a 24V AC version:
Connect a red 0.75mm² wire from the 8-pin contact on the data card la-
belled J69-8 (24V) to contact J73-104.
Connect the equipment to be controlled between contact J73-103 and con-
nector X10 in the electrical cabinet.
WD-7 DUPLUS
22
Rev. (201403)