Settings Options For Relay 11/J73 - Wexiodisk WD-7 DUPLUS Installation And User Manual

Hood type dishwasher
Hide thumbs Also See for WD-7 DUPLUS:
Table of Contents

Advertisement

Installation

3.6.3 Settings options for relay 11/J73

Set the correct function for relay 11/J73 by ensuring that the reference value on
row 105 is set to "0", which corresponds to "external dosing of drying agent", be-
fore starting on the settings on row 23.
Relay 11/J73. Set/change the dosage interval during filling and
final rinse
1.
Switch on the power to the machine.
2.
Go into S1 mode, by pressing the service button on the data card.
3.
Go to row 23.
4.
Increase the setting by pressing "P2".
5.
Reduce the setting by pressing "P3".
6.
Leave S1 mode by pressing the 0/1 button.
7.
The setting is saved when you leave S1 mode.
8.
The new value will be used during the next final rinse.
Relay 11/J73. Parallel operation with the final rinse valve
(hose pump)
1.
Switch on the power to the machine.
2.
Go into S1 mode, by pressing the service button on the data card.
3.
Go to row 23.
4.
Change the setting to "00".
5.
Leave S1 mode by pressing the 0/1 button.
6.
The setting is saved when you leave S1 mode.
7.
The new value will be used as soon as it is applicable.
Relay 11/J73. Parallel operation with the chemical pump
1.
Switch on the power to the machine.
2.
Go into S1 mode, by pressing the service button on the data card.
3.
Go to row 23.
4.
Change the setting to "99".
5.
Leave S1 mode by pressing the 0/1 button.
6.
The setting is saved when you leave S1 mode.
7.
The new value will be used as soon as it is applicable.
WD-7 DUPLUS
24
Rev. (201403)

Hide quick links:

Advertisement

Table of Contents