Wexiodisk WD-7 DUPLUS Installation And User Manual page 37

Hood type dishwasher
Hide thumbs Also See for WD-7 DUPLUS:
Table of Contents

Advertisement

Instructions for use
Changing the values – Selecting service mode
The machine must be set to service mode when the operator needs to change a
value. This is done using the control panel. The values that can be changed flash.
The displays and buttons have different functions than when the machine is in
normal operating mode.
The panel's functions in service mode.
1.
2.
3.
4.
5.
6.
7.
8.
9.
All the values are laid out in tables, with each table containing a certain number
of rows, one for each value. The table containing the values for the washing tem-
perature and washing times for the different programmes is "0.0".
The values for washing temperature and washing times are on rows 01 to 04 (in-
clusive) of table "0.0".
C
1
3
2
4
5
6
P1
7
P2
8
P3
9
6D_panel
Display for the table numbers and the row numbers of each table.
Symbol for final rinse.
Symbol for washing function.
Display of values and other information for all the row numbers in the ta-
bles.
Button for opening/closing the hood. (On machines with an automatic
hood.)
Use the P1 button to move between the table rows or to reset the values to
those last saved.
Use the P2 button to increase a value or move forwards between the ta-
bles.
Use the P3 button to reduce a value or move backwards between the ta-
bles.
Use the 0/1 button to enter or exit service mode.
WD-7 DUPLUS
33
Rev. (201403)

Hide quick links:

Advertisement

Table of Contents
loading