Installation
Relay 9/J71. Dead closing function (230V/400V machine)
To use the closing function without a power supply, follow these instructions:
•
Disconnect a blue 0,75mm² wire from connector N1 or N2 in the electrical
cabinet to contact J71-102.
•
Disconnect a black 0,75mm² wire from connector X10 to contact J71-105.
•
Contact the equipment to be controlled to contacts J71-101 and J71-105.
Relay 9/J71. Relay 9. 24V AC version
(230V/400V 3-phase machine)
To connect a 24V AC power supply to the contact, follow these instructions:
•
Disconnect a blue 0,75mm² wire from connector N1 or N2 in the electrical
cabinet to contact J71-102.
•
Disconnect a black 0,75mm² wire from connector X10 to contact J71-105.
•
Connect the equipment to be controlled to contacts J71-101 and J71-102.
There will be two wires connected to contact J71-102.
WD-7 DUPLUS
21