Bleeding The Hood Lifting Cylinder - Wexiodisk WD-90 DUO Installation And User Manual

Combination dishwasher
Hide thumbs Also See for WD-90 DUO:
Table of Contents

Advertisement

Installation instructions

3.5.9 Bleeding the hood lifting cylinder

Bleeding of the hood lifting cylinder must be performed when the dishwasher is
started up after the booster pump has been bled.
This is what you should do:
1.
2.
3.
4.
5.
6.
7.
WD-90 DUO
Start the dishwasher.
Select program P0.
Open the hood.
The dishwasher alarm may sound and the hood stops opening. Reset then
the alarm and continue.
Loosen the plug in the bleed valve at the very top of the hood and release
any air. When water starts to bubble out of the bleed valve, the plug is tight-
ened.
Close and open the hood again. Loosen the plug in the air valve and wait
until water bubbles out of the bleed valve. Tighten the plug.
Repeat this until no more air comes out of the bleed valve. The measure-
ment between the machine's bottom section and the hood when open shall
be approx. 660 mm.
26
Rev. 2.0 (202204)
25-4-05-002_1

Advertisement

Table of Contents
loading