Instructions for use
CODE
CAUSE
Er32
Non-return valve for final rinse is faulty.
Er33
Non-return valve for recirculating rinse is faulty.
IF34
The detergent alarm.
The machine has run out of detergent.
IF35
The machine is started with the door/hood
closed.
Er96
The motor safety cut-out for the pump has
tripped.
Er97
One digital input is shorted to ground.
Er98
Communication fault between the CPU and the
panel card.
Er99
Communication fault between the computer and
panel cards.
WD-7 DUPLUS
ACTION
The alarm can be reset by pressing 0/1 on the
panel. Contact service personnel if the alarm re-
curs.
The alarm can be reset by pressing 0/1 on the
panel. Contact service personnel if the alarm re-
curs.
The alarm can be reset by pressing 0/1 on the
panel.
Check the amount of detergent and refill, if nec-
essary.
Open and close the door/hood to acknowledge
the alarm.
Contact service personnel.
Contact service personnel.
The alarm can be reset by pressing 0/1 on the
panel. Contact service personnel if the alarm re-
curs.
The alarm can be reset by pressing 0/1 on the
panel. Contact service personnel if the alarm re-
curs.
48