3.2.2 Temperature Control by Mode

a. Down Sequence (text mode)
If the main thermistor (TH1) of the fixing upper roller detects any of the following levels
of temperature, the machine increases the sheet-to-sheet interval to maintain a specific fixing
temperature so as to prevent faulty fixing in continuous printing mode.
Model
Control
temperature
Control
temperature
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
iR5000 Down Sequence
50 cpm return mode
40 cpm mode
35 cpm mode
print stop
T06-302-04
iR6000 Down Sequence
60 cpm return mode
50 cpm mode
40 cpm mode
print stop
T06-302-05
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 6 FIXING SYSTEM
100-V
120/230-V
170°C
175°C
165°C
170°C
160°C
165°C
155°C
160°C
175°C
170°C
165°C
160°C
6-15 P