CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
Wiring, DC load, DC power supply PCB
3) Turn off the main power switch. Is the voltage between the follow-
ing terminals on the DC power supply PCB as indicated when the
power is turned on in about 3 min?
YES: Check the wiring from the DC power supply PCB to each load.
NO:
4.2.3 Pickup fails
General condition
1) Slide out and then in the cassette. Is the sound of the lifter falling
and the lifter motor rotating heard?
NO:
Sensor
2) In service mode (COPIER>DISPLAY>JAM), find out which sensor
has detected the jam. Is the sensor normal?
NO:
Drive motor
3) Is each drive motor mounted correctly?
NO:
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
Connector
Output voltage
J4014-1 to 5
3VA1
J4017-1 to 5
3VA2
J4003-7
3VA3
J4015-1 to 3
3VB
J4003-5
5V
J4004-1
5V
J4008-1
5V
J4009-1
5V
J4016-1, 2
5V
J4003-3, 4
12VU
J4005-1
24VU1
J4004-3
24VU2
J4009-3
24VU2
J4003-1
24VU3
J4006-1
24VU3
J4007-1, 3
24VU4
J4010-1
24VU4
J4011-1
24VU4
J4013-2
24VA
However, the above output voltages assume tolerances of ±10% in
the AC input power.
Replace the DC power supply PCB.
See "The lifter fails to move up."
Check the wiring and the sensor lever; if normal, replace the sen-
sor.
Mount the motor correctly.
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
Remarks
± 3%
± 3%
± 3%
+ 2%, - 2.5%
± 3%
± 3%
± 3%
± 3%
± 3%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
+ 7%, - 5%
4-39 T