Mounting The Blade; Removing The Developing Cylinder/Magnetic Seal - Canon iR5000 Service Manual

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

7.9.3 Mounting the Blade

Mount the blade by reversing the steps used to remove it.
1) Push the blade mounting base against
the developing assembly, and tighten
the two mounting screws.
When mounting the blade, place copy
paper on the developing cylinder first to
protect the developing cylinder.

7.9.4 Removing the Developing Cylinder/Magnetic Seal

1) Remove the developing assembly from
the machine.
2) Remove the blade unit.
3) Remove the two mounting screws [1],
and detach the gear unit [2] together
with the gear.
When removing the gear unit,
be sure to take care, as the gear
attached to the screw will be-
come free.
4) Remove the grip ring [3] mounted to
the cylinder shaft at the rear; then, re-
move the gear [4], parallel pin [5], and
push-on roll [6].
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 4 IMAGE FORMATION SYSTEM
[1]
F04-709-05
F04-709-06
[1]
[2]
[6]
[5]
[4]
[3]
4-75 P