Adjusting The Pressure Of The Separation Roller - Canon iR5000 Service Manual

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

3) Disengage the hook [4] of the separa-
tion roller assembly, and detach the
separation roller [5].

9.1.6 Adjusting the Pressure of the Separation Roller

1) Remove the right upper cover.
2) Remove the upper guide [1].
3) If double feeding or pickup failure oc-
curs during pickup, adjust the position
of the pressure spring of the separation
roller.
If double feeding occurs, remove the
mounting screw [2], and shift down the
mounting base [3]; then, fix it in hole A
using a mounting screw [2].
If pickup failure occurs, remove the
mounting screw [2], and shift the
mounting base [3] up; then, fix it in
hole B using a mounting screw [2].
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 5 PICK UP/FEEDING SYSTEM
[4]
[5]
F05-901-07
F05-901-08
Hole A
Hole B
F05-901-09
[1]
[2]
[3]