4.5 Fixing Separation Assembly

4.5.1 Removing the Upper Separation Claw

1) Slide the fixing/feeding unit out of the
machine.
2) Release the spring [1] used to open the
fixing/delivery assembly, and remove
the upper separation claw [2].
When mounting it, take care not
to chip the tip of the upper sepa-
ration claw [2].

4.5.2 Removing the Lower Separation Claw

1) Remove the fixing assembly from the
machine.
2) Remove the two screws, and detach the
lower separation claw assembly.
3) Remove the spring [1] of the lower
separation claw.
4) Remove the three screws [2], and detach
the lower separation claw support plate
[3] and the separation claw.
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 6 FIXING SYSTEM
[2]
[1]
F06-405-01
[1]
F06-405-02
[2]
[3]
F06-405-03
[2]
6-35 P