1. Selecting the Site

The site must satisfy the following conditions; if possible, pay a visit before the delivery
of the machine:
1. The temperature must be between 75° and 32.5°C (59° and 86°F) and the humidity
must be between 5% and 85%. Avoid an area near a water faucet, water boiler, humidi-
fier, or refrigerator.
2. Avoid an area near a source of fire or subject to dust or ammonium gas. If the site is
exposed to direct sunlight, provide a curtain.
3. The level of ozone generated by the machine is not likely to affect the health of people
around it. Some individuals, however, may find its odor unpleasant, calling for a good
means of ventilation.
4. Be sure that the machine's feet will be in contact with the floor, and the machine will
remain level.
5. Be sure that the machine will be at least 10 cm away from any wall, and make sure
there will be adequate space for machine operation.
6. Be sure that the room will be well ventilated and the machine will not be installed near
an air vent.
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
Body
50 cm min.
F03-100-01
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 3 INSTALLATION
10 cm min.
60 cm min.
Front cover
50 cm min.
3-1 S