When Replacing The Dc Controller Pcb - Canon iR5000 Service Manual

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

7.5 When Replacing the DC Controller PCB

1) Print out the data of user mode/service mode.
2) Replace the DC controller PCB.
3) Remove the EEPROMs (6 pc.) from the existing PCB, and mount them to the new PCB.
4) After assembling the machine, connect the power plug to the power outlet, and turn on
the main power switch.
5) Enter the values recorded on the label attached to the new DC controller PCB in service
mode:
COPIER>ADJUST>DEVELOP>D-HV-DE
COPIER>ADJUST>HV-TR>D-PRE-TR
COPIER>ADJUST>HV-TR>D-HV-TR
COPIER>ADJUST>HV-SP>D-HV-SP
6) Check to make sure that the following service mode settings are the same as the data ob-
tained before replacing the PCB:
COPIER>ADJUST>LASER>(all items)
COPIER>ADJUST>DEVELOP>(all items except D-HV-DE)
COPIER>ADJUST>DENS>(all items)
COPIER>ADJUST>BLANK>(all items)
COPIER>ADJUST>V-CONT>(all items)
COPIER>ADJUST>HV-PRI>(all items)
COPIER>ADJUST>HV-TR>(all items except D-PRE-TR and D-HV-TR)
COPIER>ADJUST>HV-SP>(all items except D-HV-SP)
COPIER>ADJUST>FEED-ADJ>(all items)
COPIER>ADJUST>CST-ADJ>(all items)
COPIER>ADJUST>MISC>(all items)
If a fault is found in the service mode settings, enter the respective setting recorded on the
service label in service mode; however, enter the settings recorded on the label attached to
the high-voltage unit for the following service mode items:
COPIER>ADJUST>DEVELOP>HVT-DE
COPIER>ADJUST>HV-TR>HVT-TR
COPIER>ADJUST>HV-TR>H-PRE-TR
COPIER>ADJUST>HV-SP>HVT-SP
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
CHAPTER 3 STANDARDS AND ADJUSTMENTS
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
3-27 T

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir6000

Table of Contents