10 Inspection and maintenance
Fig. 33 Cleaning burner
10.3 Cleaning the trap
10.4
Checking the ignition electrode
Fig. 34 Check the ignition electrode
66
10.2.4 Cleaning the burner
1. Dismantle the burner.
2. Check burner visually and if necessary clean carefully with air (e.g.
compressed air at between 30 and 70 psi (2 and 5 bar), nozzle -
burner distance approx. (0,4 inch, 1 cm).
3. Now refit all removed components
Ensure that cables do not come into contact with hot boiler parts!
Remove the trap from the boiler and clean it.
Fill the trap with fresh water and fit it.
Check the ignition electrode adjustment (between 1/8" - 1/6", 3 - 4
mm) and replace electrode if necessary (including sealing). Also
check the electrode's porcelain for hairline fractures because this may
cause spark-over.
C230 ECO-A