2 Safety

Adhere strictly to the specific safety instructions.
Can you smell gas? Proceed as follows:
Do not smoke and avoid fire and sparks.
Do not operate electrical switches.
Close the gas cock.
Open doors and windows.
Warn those present and leave the building together.
Do not use any phone in the building.
Call your gas supplier once your outside the building. If you
cannot reach them, call the fire department.
Can you smell flue or combustion gases? Proceed as follows:
Isolate the mains power supply from the boiler.
Open doors and windows.
Trace possible leaks and seal them off.
Do not use the boiler, if any part has been under water
Immediately call your service company to inspect the boiler and
replace any part of the control or gas controls.
The boiler casing is not designed for supporting other items, damage
to the casing will result if used for supporting or suspending items. Do
not walk or use the boiler casing as a ladder.
2 Safety