C230 ECO-A
* Change this parameter when converting to flue gas cascade and LPG gas (please refer to De Dietrich
America's).
Fig. 23 Setting service code
The parameters at service level may only be changed by a
qualified installer.
Changing the factory settings can result in incorrect
operation of the C230 ECO-A.
The parameters can be changed at service level as follows:
1. Press the
-key several times until the
the menu bar;
2. Select the installers menu using the
appears in the display;
3. Use the [-]-key or [+]-key to set installers code 0012;
4. Confirm with the
5. Press the
-key again; value 176°F (80°C) appears
(factory setting);
6. Lower the value, for example to 140°F (60°C), with the [-]
key;
7. Confirm the value with the
8. Set other parameters where required by selecting them with
the [-] -key or [+] -key;
9. Press the
-key twice, the boiler becomes operational.
C230 ECO-A also returns to operation if no keys are pressed
for 10 minutes.
symbol flashes in
-key, c;de
-key; p1 appears;
-key; p1 appears;
9 Commissioning
55