[G-11] Original registration sensor (S55) / Original width detection sensor-1/2/3 (S56 / S57 / S58)
(1)
Take off the ADF left cover
(
P.16-86 "[B-3] ADF left cover").
(2)
Open the jam access cover. Then remove 5
screws to take off the upper transport guide.
(3)
Disconnect the connector of each sensor.
Then take off the original registration sensor
and the original width detection sensors-1, -2
and -3.
[G-12] RADF opening/closing sensor (S65)
(1)
Take off the ADF front cover
(
P.16-85 "[B-1] ADF front cover").
(2)
Remove 1 screw to take off the RADF open-
ing/closing sensor with its bracket.
(3)
Disconnect 1 connector and remove 1
spring. Then take off the RADF opening/clos-
ing sensor.
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
Screw
Original
registration sensor
Original width
detection sensor-1
16 - 100
Upper transport guide
Screw
Screw
Fig.16-149
Original width
detection sensor-3
Original width
detection sensor-2
Fig.16-150
RADF opening/closing sensor
Fig.16-151