[A-3]
New toner supply motor (M5)
(1)
Remove 3 screws to take off the top cover.
(2)
Disconnect 1 connector, remove 2 screws,
and then take off the new toner supply motor.
[A-4]
Toner cartridge empty sensor (S10)
(1)
Remove 2 screws, and then take off the
toner cartridge empty sensor with the har-
ness.
(2)
Disconnect 1 connector from the toner car-
tridge empty sensor.
Note:
Be careful not to damage the sensor when
connecting and disconnecting the connector.
[A-5]
New toner transport motor (M6)
(1)
Remove 3 screws to take off the top cover.
e-STUDIO520/600/720/850 DEVELOPER UNIT
Toner cartridge empty sensor
Top cover
Screw
12 - 16
New toner supply motor
Screw
Connector
Fig.12-12
Fig.12-13
Screw
Fig.12-14
March 2005 © TOSHIBA TEC