[D] Cleaning blade
(1)
Take off the transfer unit.
(
P.13-6 "[A] Transfer unit")
(2)
Remove 3 screws to take off the cleaning
blade.
Notes:
1. When installing the blade, fix the boss on
both sides with the screws.
2. Be careful not to touch, scratch or dam-
age the blade.
3. After installing the blade, be sure that the
seals on both sides are not damaged.
[E]
Transfer/Transport unit
(1)
Take off the transfer unit.
(
P.13-6 "[A] Transfer unit")
(2)
Take off the fuser unit.
(
P.14-18 "[B] Fuser unit")
Note:
Make sure to take off the fuser unit and
transfer unit before the transfer/transport
unit.
March 2005 © TOSHIBA TEC
Screw
Fig.13-12
Urethan seal
Cleaning blade
Fig.13-13