Toshiba e-STUDIO520 Service Manual page 433

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

[G-6]
APS operation sensor (S64)
(1)
Take off the ADF rear cover
(
P.16-86 "[B-2] ADF rear cover").
(2)
Disconnect 1 connector and remove 1 screw.
Then take off the APS operation sensor with
its bracket.
(3)
Take off the APS sensor, separating the light
shielding section of the sensor flag from the
sensor.
[G-7]
Original intermediate transport sensor (S70)
(1)
Open the platen guide and then remove 1
screw fixing the band.
(2)
Move the platen guide to the right side. Then
release its support to take off the platen
guide.
(3)
Remove 2 screws to take off the post-scan-
ning guide.
(4)
Remove 4 screws and disconnect 1 connec-
tor. Then take off the small original transport
guide.
March 2005 © TOSHIBA TEC
APS operation sensor
Screw
Post-scanning
guide
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
16 - 97
Sensor flag
Screw
Fig.16-140
Screw
Fig.16-141
Screw
Small original
transport guide
Stepped screw
Screw
Fig.16-142