Toshiba e-STUDIO520 Service Manual page 435

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

(4)
Remove 2 screws to take off the large origi-
nal exit guide.
Note:
Be careful not to smudge the opening of the
sensor.
(5)
Remove 1 screw and disconnect 1 connec-
tor. Then take off the large original exit sen-
sor with its holder.
(6)
Remove 1 screw and take off the large origi-
nal exit sensor from its bracket.
[G-10] Read sensor (S69)
(1)
Take off the ADF left cover
(
P.16-86 "[B-3] ADF left cover").
(2)
Remove 1 screw to take off the read sensor
with its bracket.
(3)
Disconnect 1 connector and remove 1 screw.
Then take off the read sensor from its
bracket.
March 2005 © TOSHIBA TEC
Large original exit sensor
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
16 - 99
Large original exit guide
Screw
Fig.16-146
Screw
Fig.16-147
Screw
Read sensor
Fig.16-148