[H] Fuser roller
(1)
Take off the fuser unit
(
P.14-18 "[B] Fuser unit").
(2)
Take off the cleaning web unit
(
P.14-19 "[C] Cleaning web unit / Clean-
ing web").
(3)
Loosen 2 pressure screws completely.
(4)
Remove 2 screws and take off the fuser unit
cover (rear).
(5)
Open the lower separation finger unit
(
P.14-24 "[F] Lower separation finger unit
/ Lower separation finger").
(6)
Remove 2 screws and open the entrance
guide unit.
(7)
Remove 2 screws, release 2 harness clamp
and take off the bracket with releasing the
catching section.
e-STUDIO520/600/720/850 FUSER UNIT
Fuser unit cover ( rear )
Screw
Screw
14 - 26
Pressure screw
Fig.14-33
Entrance guide unit
Fig.14-34
Bracket
Harness clamp
Fig.14-35
March 2005 © TOSHIBA TEC
Screw