Panasonic S-36PU1E5A Technical Data & Service Manual page 380

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

1
5-8. External Static Pressure Setting for AC Fan Motor Model
To apply to following models
S-36PN1E5A , S-45PN1E5A , S-50PN1E5A
There are two tap connector located in indoor unit control box can be selected.
The "blue connector" is standard tap, use-as-is at shipment.
For high static pressure duct, switch Fan Motor connector to plug in
boost tap "white connector" to elevate air volume.
S-36PN1E5A
S-45PN1E5A, S-50PN1E5A
80
70
standard tap Hi
60
50
40
Lo
30
20
10
0
8
80
70
standard tap Hi
60
50
Me
40
Lo
30
20
10
0
10
P-Q CURVE
boost tap SHi
Me
3
Air Volume (m
/min.)
P-Q CURVE
boost tap SHi
20
3
Air Volume (m
/min.)