Panasonic S-36PU1E5A Technical Data & Service Manual page 19

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

Single-Type
1-1. Unit Specifi cations
PE1
1. 4-Way Cassette Type S-60PU1E5A / U-60PE1E5A
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool (DBT)
Operation
Condition
Heat (DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PU1E5A
CZ-KPU21
ø, Hz
1ø 50Hz
V
220
230
kW
6.0
6.0
20500
20500
A
0.32
0.31
W
35
35
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
36/31/28
53/48/45
dB-A
kW
7.0
7.0
23900
23900
A
0.30
0.30
W
35
35
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
36/31/28
53/48/45
dB-A
-
-
0.32/35
0.31/35
-
-
-
60
L/h(Pt/h)
3.4 (7.1)
Pa
-
3
/min)
21/17/14 (742/600/494)
3
/min)
21/17/14 (742/600/494)
3
/min)
3
/min)
256 (10-3/32)
840 (33-3/32)
840 (33-3/32)
298
929
929
24 (53)
30 (67)
11 (12)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-60PE1E5A
-
ISO5151 / EN14511 / EN14825 / EN12102
1ø 50Hz
240
220
230
6.0
20500
0.30
7.15
6.90
35
1.445k
1.445k
1.480k
1.480k
-
740
-
4.05
4.05 / A
-
-
6.0
-
-
7.4
-
-
284
-
-
A++
-
92
91
48/-
65/-
7.0
23900
0.29
8.50
8.20
35
1.775k
1.775k
1.810k
1.810k
-
3.87
3.87 / A
-
-
6.0
-
-
-10
-
-
4.1
-
-
2047
-
-
A+
-
95
94
-
-
50/-
67/-
-
0.30/35
18.0/3.800k
18.0/3.930k
-
8.50/1.7k
8.20/1.7k
-
90
-
60
60
R410A
2.00k
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
68 (150)
76 (168)
2 (3)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-9
240
Min
Max
2.5
7.1
8500
24200
6.70
-
-
1.445k
-
-
1.480k
450
2.000k
-
-
-
4.05
5.56
3.55
-
-
-
-
90
-
-
2.0
8.0
6800
27300
7.95
-
-
1.775k
-
-
1.810k
400
2.480k
3.87
5.00
3.23
-
-
-
-
-
93
-
-
18.0/4.060k
7.95/1.7k
(2119)
(2119)
(70.5)
/
/
/
/
/
/
/
/
/
~
~
1

Advertisement

Table of Contents
loading

Table of Contents