Panasonic S-36PU1E5A Technical Data & Service Manual page 173

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

Single -Type
1-1. Unit Specifi cations
PEY1
3. Wall Mounted Type S-100PK1E5A / U-100PEY1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-100PK1E5A
-
ø, Hz
1ø 50Hz
V
220
230
kW
9.0
9.0
30700
30700
A
0.61
0.59
W
65
65
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
49/45/41
66/60/55
dB-A
kW
9.0
9.0
30700
30700
A
0.62
0.60
W
65
65
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
49/45/41
66/60/55
dB-A
-
-
0.62/65
0.60/65
-
-
-
47
L/h(Pt/h)
5.4
Pa
-
3
/min)
19/16.5/13 (671/583/459)
3
/min)
19/16.5/13 (671/583/459)
3
/min)
3
/min)
300 (11-1/32)
1065 (41-23/64)
230 (9-1/32)
310
1140
380
14.5 (32)
18 (40)
15 (16)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-100PEY1E8
-
ISO5151 / EN14511 / EN14825 / EN12102
3ø 50Hz
240
380
400
9.0
30700
0.55
5.40
5.15
65
3.305k
3.305k
3.370k
3.370k
-
1685
-
2.67
2.67 / D
-
-
9.0
-
-
5.7
-
-
553
-
-
A+
-
93
93
-
-
54/-
70/-
9.0
30700
0.56
3.85
3.65
65
2.365k
2.365k
2.430k
2.430k
-
3.70
3.70 / A
-
-
9.0
-
-
-7
-
-
3.8
-
-
3316
-
-
A
-
93
94
-
-
54/-
70/-
-
0.56/65
9.0/5.510k
9.0/5.800k
-
5.40/1.7k
5.15/1.7k
-
90
(11.3)
-
76
67
R410A
2.60k
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
73 (161)
81 (179)
2 (3)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-163
415
Min
Max
2.7
9.7
9200
33100
4.95
-
-
3.305k
-
-
3.370k
530
3.800k
-
-
-
2.67
5.09
2.55
-
-
-
-
93
-
-
2.1
10.5
7200
35800
3.55
-
-
2.365k
-
-
2.430k
410
3.000k
3.70
5.12
3.50
-
-
-
-
-
93
-
-
9.0/6.020k
4.95/1.7k
(2684)
(2366)
(91.7)
/
/
/
/
/
/
/
/
/
~
~
1