1-13. Capacity Table

1. Cooling Capacity Performance Data

Combination of Single Unit
4-Way Cassette Type
Power
Model
Source
220V
230V
S-50PU1E5A
240V
U-50PE1E5
50Hz
1 phase
Ambient
Return
25°C
Air
DB
WB
TC
SHC
IPT
16
5.9
4.3
1.61
23
19
6.4
3.4
1.67
22
7.0
2.4
1.74
16
5.9
4.9
1.61
25
19
6.4
4.0
1.67
22
7.0
3.0
1.74
16
5.9
5.5
1.61
27
19
6.4
4.5
1.67
22
7.0
3.6
1.74
16
5.9
5.9
1.61
29
19
6.4
5.2
1.67
22
7.0
4.2
1.74
16
5.9
5.9
1.61
32
19
6.4
5.2
1.67
22
7.0
4.2
1.74
Outdoor air intake temp(°C D.B.)
30°C
35°C
TC
SHC
IPT
TC
SHC
5.6
4.2
1.74
5.2
4.0
6.0
3.2
1.82
5.6
3.0
6.5
2.2
1.89
6.1
2.1
5.6
4.8
1.74
5.2
4.6
6.0
3.8
1.82
5.6
3.6
6.5
2.8
1.89
6.1
2.7
5.6
5.4
1.74
5.2
5.2
6.0
4.4
1.82
5.6
4.2
6.5
3.4
1.89
6.1
3.3
5.6
5.6
1.74
5.2
5.2
6.0
5.0
1.82
5.6
4.8
6.5
4.0
1.89
6.1
3.8
5.6
5.6
1.74
5.2
5.2
6.0
5.0
1.82
5.6
4.8
6.5
4.0
1.89
6.1
3.8
1-376
TC
:Cooling Capacity
SHC :Sensible Heat Capacity
IPT :Cooling Power Consumption
40°C
IPT
TC
SHC
IPT
TC
1.92
5.0
3.9
2.13
3.9
2.00
5.4
2.9
2.22
4.2
2.08
5.9
2.0
2.31
4.6
1.92
5.0
4.5
2.13
3.9
2.00
5.4
3.5
2.22
4.2
2.08
5.9
2.6
2.31
4.6
1.92
5.0
5.0
2.13
3.9
2.00
5.4
4.1
2.22
4.2
2.08
5.9
3.2
2.31
4.6
1.92
5.0
5.0
2.13
3.9
2.00
5.4
4.7
2.22
4.2
2.08
5.9
3.8
2.31
4.6
1.92
5.0
5.0
2.13
3.9
2.00
5.4
4.7
2.22
4.2
2.08
5.9
3.8
2.31
4.6
unit : kW
46°C
SHC
IPT
3.4
1.40
2.5
1.46
1.6
1.52
3.9
1.40
3.1
1.46
2.1
1.52
3.9
1.40
3.7
1.46
2.7
1.52
3.9
1.40
4.2
1.46
3.3
1.52
3.9
1.40
4.2
1.46
3.3
1.52