Model No.
INDOOR UNIT
4-Way Cassette
(U1 type)
S-36PU1E5A
S-71PU1E5A
S-45PU1E5A
S-100PU1E5A
S-50PU1E5A
S-125PU1E5A
S-60PU1E5A
S-140PU1E5A
Ceiling
(T2 type)
S-36PT2E5A
S-71PT2E5A
S-45PT2E5A
S-100PT2E5A
S-50PT2E5A
S-125PT2E5A
S-60PT2E5A
S-140PT2E5A
Low Silhouette Ducted
S-36PF1E5A
S-71PF1E5A
S-45PF1E5A
S-100PF1E5A
S-50PF1E5A
S-125PF1E5A
S-60PF1E5A
S-140PF1E5A
OUTDOOR UNIT
Single Split
(Single-phase)
PE1 Type
U-71PE1E5A
U-100PE1E5A
U-50PE1E5
U-125PE1E5A
U-60PE1E5A
U-140PE1E5A
Single Split
(3-phase)
PE1 Type
U-71PE1E8A
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
Single Split
(Single-phase)
PEY1 Type
U-71PEY1E5
U-100PEY1E5
U-125PEY1E5
U-60PEY1E5
Single Split
(3-phase)
PEY1 Type
U-100PEY1E8
U-125PEY1E8
U-140PEY1E8
AMP Air Conditioning
Low Silhouette Ducted
(F1 type)
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
Antes de operar la unidad, lea atentamente estas instrucciones de
(F1 type)
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
Prima di utilizzare l'unità, leggere a fondo queste istruzioni per l'uso e
conservarle come riferimento futuro.
NEDERLANDS
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.

Operating Instructions

Ceiling
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
www.ampair.co.uk | sales@ampair.co.uk

Air Conditioner

4-Way Cassette
(T2 type)
10 ~ 17
18 ~ 25
26 ~ 33
34 ~ 41
42 ~ 49
50 ~ 57
58 ~ 65
66 ~ 73
(U1 type)
2 ~ 9
E
NGLISH
F
RANÇAIS
E
SPAÑOL
D
EUTSCH
I
TALIANO
N
EDERLANDS
P
ORTUGUÊS
E
ΛΛΗΝΙΚΆ
Б
ЪЛГАРСКИ
F569616

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic U-140PEY1E8

  • Page 1: Operating Instructions

    тези инструкции и ги запазете, за да можете да правите справки с тях и — U-71PEY1E5 в бъдеще. — U-100PEY1E5 — U-125PEY1E5 U-60PEY1E5 — Single Split (3-phase) PEY1 Type — — — U-100PEY1E8 — U-125PEY1E8 — U-140PEY1E8 Panasonic Corporation F569616 1006 Kadoma, Kadoma City, Osaka, Japan AMP Air Conditioning www.ampair.co.uk | sales@ampair.co.uk...
  • Page 2: Table Of Contents

    Thank you for purchasing this Panasonic product. WARNING This product is a commercial air conditioner indoor unit. Installation Instructions attached. Contents Confi rm to authorized dealer or specialist on usage of specifi ed refrigerant type. Using of refrigerant other than the Safety Precautions ............
  • Page 3 CAUTION This appliance is intended to be used Provide a power outlet to be by expert or trained users in shops,in used exclusively for each unit, light industry and on farms, or for and a power supply disconnect, commercial use by lay persons. circuit breaker and earth leakage breaker for overcurrent protection This appliance can be used by...
  • Page 4: Precautions For Use

    U-100PEY1E5, U-100PEY1E8, U-125PEY1E5, Locations where excessively high heat-generating ob-   U-125PEY1E8, U-140PEY1E8 jects are placed. Attention: Information for Users on Collection and Disposal of Old Equipment and Used Batteries Avoid installing the outdoor unit where salty sea water can ...
  • Page 5: Names Of Parts

    Names of Parts INDOOR UNIT OUTDOOR UNIT Water drain Air intake Air intake Air intake Ceiling panel (optional) Air outlet (4 locations) Air intake grille Air outlet Air outlet (air intake) Air outlet U1 type (4-Way Cassette) (50 type) (60, 71 type) (100, 125, 140 type) Air outlet PEY1...
  • Page 6: Adjusting Airfl Ow Direction

    Adjusting Airfl ow Direction This section is described in the instruction manual supplied with the timer remote contoller (CZ-RTC2). Regarding the High-spec Wired Remote Controller (CZ-RTC3), refer to the Operating Instructions supplied with the model CZ-RTC3. Adjusting the upward and downward motion of airfl ow direction (U1 and T2 types only) ...
  • Page 7: Indoor Units

    Adjusting airfl ow direction for multiple indoor units (Timer remote controller only) When operating multiple indoor units using 1 remote controller, airfl ow direction can be adjusted for indoor each unit individually or all units at the same time. Unit No. ...
  • Page 8: Maintenance

    Maintenance Indoor unit (e.g. U1 type) WARNING Air outlet For safety, be sure to turn the air conditioner off and dis-   connect the power before cleaning. Air intake (Otherwise, electric shock or injury may result because the fan is rotating at high speed.) Do not pour water on the indoor unit.
  • Page 9 Troubleshooting Check before consulting or requesting services. Symptom Cause / Action Sound like streaming water is heard • Sound of refrigerant liquid fl owing inside unit during operation or after operation. • Sound of drainage water through drain pipe Noise Cracking noise is heard during operation Sound due to temperature changes of parts or when operation stops.

Table of Contents