1-13. Capacity Table
1. Cooling Capacity Performance Data
Combination of Single Unit
Ceiling Type
Ambient
Power
Model
Return
Source
DB
23
25
220V
230V
S-140PT2E5A
240V
U-140PE1E5A
27
50Hz
(U-140PE1E8A)
1phase
(3phase)
29
32
25°C
Air
WB
TC
SHC
IPT
TC
16
13.6
9.6
4.58
13.6
19
14.6
7.5
4.78
14.6
22
16.0
5.5
4.95
16.0
16
14.1
11.3
4.66
14.1
19
15.1
9.2
4.86
15.1
22
16.5
6.9
5.03
16.5
16
14.6
13.0
4.74
14.6
19
15.6
10.9
4.94
15.6
22
17.1
8.6
5.11
17.1
16
14.8
14.6
4.75
14.8
19
15.8
12.3
4.96
15.8
22
17.3
10.2
5.13
17.3
16
15.0
14.8
4.76
15.0
19
16.1
12.5
4.97
16.1
22
17.6
10.4
5.14
17.6
Outdoor air intake temp(°C D.B.)
30°C
35°C
SHC
IPT
TC
SHC
IPT
9.6
4.93
13.1
9.3
5.24
7.5
5.14
14.0
7.2
5.47
5.4
5.32
15.4
5.3
5.65
11.3
5.01
13.6
11.0
5.33
9.1
5.22
14.5
8.8
5.56
7.0
5.40
15.9
6.7
5.75
13.1
5.09
14.0
12.7
5.42
10.8
5.31
15.0
10.4
5.65
8.7
5.49
16.4
8.4
5.85
14.6
5.10
14.3
14.1
5.43
12.4
5.32
15.2
12.0
5.66
10.3
5.51
16.7
10.0
5.86
14.8
5.12
14.5
14.3
5.44
12.6
5.34
15.4
12.1
5.68
10.5
5.52
16.9
10.1
5.87
1-381
TC
:Cooling Capacity
SHC :Sensible Heat Capacity
IPT :Cooling Power Consumption
40°C
46°C
TC
SHC
IPT
TC
SHC
12.2
9.0
5.45
8.9
7.5
13.0
6.9
5.68
9.5
5.4
14.3
4.8
5.88
10.4
3.5
12.6
10.7
5.54
9.2
9.1
13.5
8.5
5.78
9.9
7.0
14.8
6.4
5.98
10.8
4.9
13.1
12.5
5.63
9.5
9.4
14.0
10.2
5.88
10.2
8.6
15.3
8.0
6.08
11.2
6.5
13.3
13.1
5.65
9.7
9.6
14.2
11.8
5.89
10.4
10.1
15.5
9.5
6.09
11.3
7.9
13.4
13.2
5.66
9.8
9.7
14.4
11.9
5.91
10.5
10.2
15.7
9.7
6.11
11.5
8.0
1
unit : kW
IPT
4.45
4.65
4.81
4.53
4.72
4.89
4.60
4.80
4.97
4.62
4.81
4.98
4.63
4.83
4.99