Panasonic S-36PU1E5 Operating Instructions Manual

Panasonic S-36PU1E5 Operating Instructions Manual

4-way; low silhouette; single split

Advertisement

ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
РУССКИЙ
УКРАЇНСЬКА
Operating Instructions
Air Conditioner
Model No.
4-Way
Low Silhouette
Cassette
Ducted
S-36PU1E5
S-36PF1E5
S-45PU1E5
S-45PF1E5
S-50PU1E5
S-50PF1E5
S-60PU1E5
S-60PF1E5
S-71PU1E5
S-71PF1E5
S-100PU1E5
S-100PF1E5
S-125PU1E5
S-125PF1E5
S-140PU1E5
S-140PF1E5
© Panasonic Corporation 2012
Unauthorized copying and distribution is a
violation of law.
Single Split
(Single-phase)
(3-phase)
U-60PE1E5
U-71PE1E5
U-71PE1E8
U-100PE1E5
U-100PE1E8
U-125PE1E5
U-125PE1E8
U-140PE1E5
U-140PE1E8
2 ~ 13
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74 ~ 85
86 ~ 97
98 ~ 109
110 ~ 121
122 ~ 134
F568247

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-36PU1E5

  • Page 1 50 ~ 61 NEDERLANDS 62 ~ 73 PORTUGUÊS 74 ~ 85 EΛΛΗΝΙΚΆ 86 ~ 97 БЪЛГАРСКИ 98 ~ 109 РУССКИЙ 110 ~ 121 УКРАЇНСЬКА 122 ~ 134 © Panasonic Corporation 2012 Unauthorized copying and distribution is a violation of law. F568247...
  • Page 2: Table Of Contents

    CONTENTS Page PRODUCT INFORMATION ......................2 SAFETY PRECAUTIONS......................2 INSTALLATION LOCATION......................3 ELECTRICAL REQUIREMENTS ....................3 SAFETY INSTRUCTIONS......................4 INFORMATION..........................6 OPERATION..........................7 ADJUSTING AIRFLOW DIRECTION ....................8 ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) ....................10 SPECIAL REMARKS ........................11 CARE AND CLEANING ......................11 TROUBLESHOOTING ........................12 CHECK BEFORE REQUIRING SERVICES................13 TIPS FOR ENERGY SAVING .....................13...
  • Page 3: Installation Location

    INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
  • Page 4: Safety Instructions

    SAFETY INSTRUCTIONS • Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. • This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
  • Page 5 • The compressor may occasionally stop during thunderstorms. NOTICE This is not a mechanical failure. The unit automatically recovers after a few minutes. • The English text is the original instructions. Other languages are translation of the original instructions. Stop using the product when any abnormality/failure occurs and disconnect the power plug.
  • Page 6: Information

    INFORMATION Operation Condition Use this air conditioner under the following temperature range. Indoor temperature range: Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT) Heating mode 16°C ~ 30°C (*DBT) Outdoor temperature range: Cooling mode -15°C ~ 46°C (*DBT) Heating mode -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT) *DBT: Dry bulb temperature *WBT: Wet bulb temperature...
  • Page 7: Operation

    OPERATION Names of Parts INDOOR UNIT U1 Type (4-WAY CASSETTE) F1 Type (LOW SILHOUETTE DUCTED) Water drain Suspension Air outlet duct Bolt anchor bolt Ceiling panel (optional) Air outlet Air-outlet grille Indoor unit (4 locations) Ceiling material Air intake grille (air intake) Wireless Remote Controller (Optional parts) Refer to the Operating Instructions attached to the...
  • Page 8: Adjusting Airflow Direction

    ADJUSTING AIRFLOW DIRECTION The functions differ depending on the indoor unit used. The airflow direction cannot be set using the remote controller for any unit which is not listed below. U1 type. • Never use your hands to move the flap (vertical airflow flap) that is controlled using the remote controller.
  • Page 9 ADJUSTING AIRFLOW DIRECTION (CONTINUED) U1 type air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller. Do not move the flap with your hands. 4-way (U1 type) •...
  • Page 10: Adjusting Airflow Direction For Multiple Indoor Units Using Single Remote Controller (Wired)

    ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) • The airflow direction cannot be set using the remote controller for the concealed duct type (F1). • If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below).
  • Page 11: Special Remarks

    SPECIAL REMARKS ‘‘DRY’’ Operation How it works • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. • In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating.
  • Page 12: Troubleshooting

    TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT Symptom Cause Noise Sound like streaming water during •...
  • Page 13: Check Before Requiring Services

    CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Air conditioner does not run at Power failure or after power failure Press ON/OFF operation button on remote control all although power is turned unit again. Operation button is turned off. • Switch on power if breaker is turned off. •...
  • Page 14: Specifications

    SPECIFICATIONS 4-Way Cassette (U1 type) Model Name S-36PU1E5 S-45PU1E5 S-50PU1E5 S-60PU1E5 S-71PU1E5 Power Source 220 - 230 - 240 V, single-phase, 50 Hz Cooling Capacity BTU/h 12,300 15,400 17,100 20,500 24,200 Heating Capacity BTU/h 14,300 17,700 19,100 23,900 27,300 High...
  • Page 15 SPECIFICATIONS Low Silhouette Ducted (F1 type) Model Name S-36PF1E5 S-45PF1E5 S-50PF1E5 S-60PF1E5 S-71PF1E5 Power Source 220 - 230 - 240 V, single-phase, 50 Hz Cooling Capacity BTU/h 12,300 15,400 17,100 20,500 24,200 Heating Capacity BTU/h 14,300 17,700 19,100 23,900 27,300 High dB(A) Sound Pressure Level...
  • Page 16 SPECIFICATIONS Single Split Outdoor Unit Model Name U-60PE1E5 U-71PE1E5 U-100PE1E5 U-125PE1E5 U-140PE1E5 Power Source 220 - 230 - 240 V, single-phase, 50 Hz 10.0 12.5 14.0 Cooling Capacity BTU/h 20,500 24,200 34,100 42,700 47,800 11.2 14.0 16.0 Heating Capacity BTU/h 23,900 27,300 38,200...
  • Page 17 CARACTÉRISTIQUES / ESPECIFICACIONES / TECHNISCHE DATEN / SPECIFICATIONS SPECIFICHE / SPECIFICATIE / ESPECIFICAÇÕES English Français Español Deutsch 4-Way Cassette (U1 type) Cassette 4 voies (Type U1) Cassette de 4 vías (tipo U1) 4-Weg Kassette (Typ U1) Ceiling (T1 type) Plafond (Type T1) Techo (tipo T1) Deckenmontage (Typ T1) High Static Pressure Ducted (E1...
  • Page 18 CARACTÉRISTIQUES / ESPECIFICACIONES / TECHNISCHE DATEN / SPECIFICATIONS SPECIFICHE / SPECIFICATIE / ESPECIFICAÇÕES English Français Español Deutsch Model Name Nom du modèle Nombre del modelo Modellbezeichnung Power Source Source d'alimentation Fuente de alimentación Spannungsquelle Cooling Capacity Capacité de refroidissement Capacidad de refrigeración Kühlleistung Heating Capacity Capacité...
  • Page 19 ΠΡΟΔΙΑΓΡΑΦΕΣ / СПЕЦИФИКАЦИИ / SPECIFICATIONS ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ / СПЕЦИФІКАЦІА Ελληνικη English Български Русский Українська Κασέτας 4-δρομο (Τύπος 4-Way Cassette (U1 type) Οροφής (Τύπος T1) Ceiling (T1 type) Αγωγός υψηλής στατικής High Static Pressure πίεσης (Τύπος E1) Ducted (E1 type) Κασέτας 4-δρομο 60x60 4-Way Cassette 60x60 (Τύπος...
  • Page 20 Compliance with regulation 842/EC/2006 Article 7(1) requirements English DO NOT VENT R410A INTO THE ATMOSPHERE: R410A IS A FLUORINATED GREENHOUSE GAS, COVERED BY THE KYOTO PROTOCOL, WITH A GLOBAL WARMING POTENTIAL (GWP) = 1975. Conformité aux exigences de l’article 7 (1) de la réglementation 842/EC/ Français 2006 NE PAS METTRE LE R410A À...
  • Page 21 BE0112-0 Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany Printed in China...

Table of Contents