Panasonic S-36PU1E5A Technical Data & Service Manual page 126

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

1
Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
5. Ducted Type S-36PN1E5A×2 / U-71PE1E8A
INDOOR
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION TOTAL kWh
O
EER/EER CLASS
O
Pdsign
L
Erp
SEER
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W) 0.60×2/130×2 0.62×2/140×2 0.63×2/150×2
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
I/D AIR
FLOW
HEAT
COOL
O/D AIR
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-36PN1E5A×2
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
7.1
BTU/h
24200
A
0.42×2
W
90×2
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
40/38/35
Power Level dB
57/55/52
dB-A
Power Level dB
kW
8.0
BTU/h
27300
A
0.42×2
W
90×2
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
40/38/35
Power Level dB
57/55/52
dB-A
Power Level dB
-
L/h(Pt/h)
4.2
Pa
50 (MIN10 - MAX80)
m
3
/min (ft
3
/min)
[14/12/10 (494/424/353)]×2
3
3
m
/min (ft
/min)
[14/12/10 (494/424/353)]×2
3
3
m
/min (ft
/min)
m
3
/min (ft
3
/min)
250 (9-27/32)
780 (+100) (30-23/32) (+3-15/16)
650 (25-19/32)
29 (64)
34 (75)
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
CZ-P155BK1
ISO13253 / EN14511 / EN14825 / EN12102
230
240
380
7.1
7.1
24200
24200
0.43×2
0.44×2
3.25
94×2
98×2
2.010k
-
2.190k
-
-
-
-
3.24
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
8.0
8.0
27300
27300
0.43×2
0.44×2
3.35
94×2
98×2
2.120k
-
2.300k
-
-
3.48
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
96
-
-
-
7.0/4.150k
-
-
3.35/2.0k
-
60×2
(2.1×2)
(8.8)
60
60
R410A
345
1007
777
8 (9)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
5 ~ 50
(16.4 ~ 164.0)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-116
U-71PE1E8A
3ø 50Hz
400
415
3.10
3.00
2.012k
2.014k
2.200k
2.210k
1100
-
3.23 / A
3.21
7.1
-
4.7
-
531
-
B
-
94
93
48/-
65/-
3.20
3.10
2.122k
2.124k
2.310k
2.320k
3.46 / B
3.45
6.1
-
-9
-
3.8
-
2245
-
A
-
96
95
-
-
50/-
67/-
7.0/4.360k
7.0/4.530k
3.20/2.0k
3.10/2.0k
-
90
-
(2119)
(2119)
2.35k
(82.9)
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
71 (157)
79 (174)
2 (3)
-15°C ~ 46°C
-20°C ~ 24°C
fl ared type, 5.0(16.4)
(49.2/98.4)
Min
Max
2.5
8.0
8500
27300
-
-
-
-
660
2.750k
-
-
3.79
2.91
-
-
2.0
9.0
6800
30700
-
-
-
-
600
3.000k
3.33
3.00
-
-
/
/
/
/
/
/
/
/
/
~
~