Panasonic S-36PU1E5A Technical Data & Service Manual page 160

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

1
Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PEY1
2. Ceiling Type S-71PT2E5A×2 / U-140PEY1E8
INDOOR
PANEL
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION TOTAL kWh
O
EER/EER CLASS
O
Pdsign
L
SEER
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
I/D AIR
COOL
FLOW
HEAT
COOL
O/D AIR
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-71PT2E5A×2
MODEL
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
14.0
BTU/h
47800
A
0.45×2
W
55×2
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
39/35/31
Power Level dB
57/53/49
dB-A
Power Level dB
kW
14.0
BTU/h
47800
A
0.45×2
W
55×2
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
39/35/31
Power Level dB
57/53/49
dB-A
Power Level dB
0.45×2/55×2 0.44×2/55×2 0.43×2/55×2
-
L/h(Pt/h)
9.0
Pa
3
3
m
/min (ft
/min)
[21/18/15.5 (742/636/547)]×2
3
3
m
/min (ft
/min)
[21/18/15.5 (742/636/547)]×2
m
3
/min (ft
3
/min)
3
3
m
/min (ft
/min)
235 (9-1/4)
1275 (50-3/16)
690 (27-5/32)
33 (73)
42 (93)
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
CZ-P155BK1
ISO5151 / EN14511 / EN12102
230
240
380
14.0
14.0
47800
47800
0.44×2
0.43×2
7.40
55×2
55×2
4.590k
-
4.700k
-
-
-
-
2.98
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
14.0
14.0
47800
47800
0.44×2
0.43×2
5.65
55×2
55×2
3.500k
-
3.610k
-
-
3.88
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
-
-
-
10.0/6.19k
-
-
7.40/3.0k
-
74
(4.5×2)
(18.9)
-
135
120
R410A
360
1340
820
9 (10)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
5 ~ 50
(16.4 ~ 164.0)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-150
U-140PEY1E8
3ø 50Hz
400
415
11300
7.05
6.80
4.590k
4.590k
4.700k
4.700k
2350
-
2.98 / C
2.98
-
-
-
-
-
-
-
-
94
94
-
-
54/-
71/-
14000
5.35
5.20
3.500k
3.500k
3.610k
3.610k
3.88 / A
3.88
-
-
-
-
-
-
-
-
-
-
94
94
-
-
53/-
70/-
10.0/6.51k
10.0/6.75k
7.05/3.0k
6.80/3.0k
-
90×2
-
(4767)
(4238)
3.40k
(119.9)
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98 (216)
108 (238)
1 (2)
-10°C ~ 43°C
-15°C ~ 24°C
fl ared type, 5.0(16.4)
(49.2/98.4)
Min
Max
3.8
15.0
51200
-
-
-
-
840
5.700k
-
-
3.93
2.63
-
-
4.1
16.0
54600
-
-
-
-
900
5.210k
4.56
3.07
-
-
/
/
/
/
/
/
/
/
/
~
~

Advertisement