1
How to connect wiring to the terminal
Air Purging with a Vacuum Pump (for Test Run) Preparation
(1) Cut the wire end with cutting pliers, then strip the
insulation to expose the stranded wire about 10 mm
and tightly twist the wire ends.
(2) Using a Phillips head screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring pressure terminal.
(4) Put the removed terminal screw through the ring
pressure terminal and then replace and tighten the
terminal screw using a screwdriver.
Assembling parts for outdoor unit cover
Cord clamp
(Field supply)
Cord clamp C
1-270
Stranded wire
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
Terminal board
Earth
Cord clamp A
Cord clamp B
Terminal cover
Pipe cover
Screw
Ring
pressure
terminal
Screw and
Special
washer
Ring
pressure
terminal
Wire

Advertisement