Panasonic S-36PU1E5A Technical Data & Service Manual

Panasonic S-36PU1E5A Technical Data & Service Manual

Hide thumbs Also See for S-36PU1E5A:

Advertisement

Quick Links

TECHNICAL DATA & SERVICE MANUAL
R410A Models
Model No.
Indoor Units
Indoor
Type
Units Type
U1
4-Way Cassette
S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A
T2
Ceiling
S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A
K1
Wall Mounted
S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A S-71PK1E5A
Low Silhouette
F1
S-36PF1E5A S-45PF1E5A S-50PF1E5A S-60PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5A
Ducted
N1
Ducted
S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5A
Outdoor Units
Type
Outdoor Units Type
Single Split (1-phase)
PE1
Single Split (3-phase)
Single Split (1-phase)
PEY1
Single Split (3-phase)
85464849331000
Indoor Unit
4-Way Cassette
Ceiling
Wall Mounted
Low Silhouette Ducted
Ducted
36
45
50
U-50PE1E5
50
60
71
60
71
U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A
U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A
U-60PEY1E5
U-71PEY1E5 U-100PEY1E5 U-125PEY1E5
Order No. SBPAC1403009CE  
Outdoor Unit
100
125
S-125PT2E5A S-140PT2E5A
S-100PK1E5A
100
125
U-100PEY1E8 U-125PEY1E8
REFERENCE NO.
140
140
U-140PEY1E8
SM830231-00

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-36PU1E5A

  • Page 1 Ducted R410A Models Model No. Indoor Units Indoor Type Units Type 4-Way Cassette S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A Ceiling S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5A Wall Mounted S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A S-71PK1E5A S-100PK1E5A – –...
  • Page 2 Check of Density Limit The standards for minimum room volume are as follows. (1) No partition (shaded portion) The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. The refrigerant (R410A), which is used in the air conditioner, is safe, without the toxicity or combustibility of ammonia, and is not restricted by laws imposed to protect the ozone layer.
  • Page 3 IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
  • Page 4 Combination of Indoor and Outdoor Units Single-phase S-36PU1E5A x2 S-45PU1E5A x3 S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A U-71PE1E5A U-125PE1E5A U-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A S-36PU1E5A x3 S-50PU1E5A x2 S-60PU1E5A x2 S-71PU1E5A x2 U-100PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A S-36PU1E5A x4 S-50PU1E5A x3...
  • Page 5 Combination of Indoor and Outdoor Units 3-phase S-36PU1E5A x2 S-45PU1E5A x3 S-50PU1E5A x2 S-60PU1E5A x2 S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A U-71PE1E8A U-125PE1E8A U-100PE1E8A U-125PE1E8A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A S-36PU1E5A x3 S-50PU1E5A x3 S-71PU1E5A x2 U-100PE1E8A U-140PE1E8A U-140PE1E8A S-36PU1E5A x4 U-125PE1E8A S-36PT2E5A x2...
  • Page 6 Combination of Indoor and Outdoor Units PEY1 Single-phase S-36PU1E5A x2 S-50PU1E5A x2 S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-71PEY1E5 U-100PEY1E5 P128 P129 P130 P132 P133 P134 S-60PU1E5A x2 U-125PEY1E5 P131 S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-36PT2E5A x2 S-50PT2E5A x2...
  • Page 7: Table Of Contents

    —— CONTENTS —— Section 1. SPECIFICATIONS....................1-1 1-1. Unit Specifications ........................1-2. Dimensional Data ........................ 1-241 1-3. Refrigerant Flow Diagram ....................1-255 1-4. Operating Range ......................... 1-258 1-5. Capacity Correction Graph According to Temperature Condition ........1-259 1-6. Noise Criterion Curves ......................
  • Page 8: Dimensional Data

    1. SPECIFICATIONS 1-1. Unit Specifications ....................1. 4-Way Cassette Type (U1) ....................... 2. Ceiling Type (T2) ..........................1-28 3. Wall Mounted Type (K1) ........................1-54 4. Low Silhouette Ducted Type (F1) ..................... 1-76 5. Ducted Type (N1) ..........................1-102 PEY1 1.
  • Page 9: Low Silhouette Ducted Type (F1)

    Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×2 / U-71PE1E5A INDOOR MODEL S-36PF1E5A×2 OUTDOOR MODEL U-71PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 7.10 7.10...
  • Page 10 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×3 / U-100PE1E5A INDOOR MODEL S-36PF1E5A×3 OUTDOOR MODEL U-100PE1E5A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 11 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×4 / U-125PE1E5A INDOOR MODEL S-36PF1E5A×4 OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 12 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-45PF1E5A×3 / U-125PE1E5A INDOOR MODEL S-45PF1E5A×3 OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 13 Single-Type 1-1. Unit Specifications 4. Low Silhouette Ducted Type S-50PF1E5A / U-50PE1E5 INDOOR MODEL S-50PF1E5A PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100...
  • Page 14 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-50PF1E5A×2 / U-100PE1E5A INDOOR MODEL S-50PF1E5A×2 OUTDOOR MODEL U-100PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 15 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-50PF1E5A×3 / U-140PE1E5A INDOOR MODEL S-50PF1E5A×3 OUTDOOR MODEL U-140PE1E5A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 16 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-60PF1E5A / U-60PE1E5A INDOOR MODEL S-60PF1E5A OUTDOOR MODEL U-60PE1E5A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 6.00 6.00 6.00...
  • Page 17 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-60PF1E5A×2 / U-125PE1E5A INDOOR MODEL S-60PF1E5A×2 OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 18 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-71PF1E5A / U-71PE1E5A INDOOR MODEL S-71PF1E5A OUTDOOR MODEL U-71PE1E5A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 7.10 7.10 7.10...
  • Page 19 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-71PF1E5A×2 / U-140PE1E5A INDOOR MODEL S-71PF1E5A×2 OUTDOOR MODEL U-140PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 20 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-100PF1E5A / U-100PE1E5A INDOOR MODEL S-100PF1E5A OUTDOOR MODEL U-100PE1E5A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 21 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-125PF1E5A / U-125PE1E5A INDOOR MODEL S-125PF1E5A OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 22 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-140PF1E5A / U-140PE1E5A INDOOR MODEL S-140PF1E5A OUTDOOR MODEL U-140PE1E5A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 23 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×2 / U-71PE1E8A INDOOR MODEL S-36PF1E5A×2 OUTDOOR MODEL U-71PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 7.10 7.10...
  • Page 24 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×3 / U-100PE1E8A INDOOR MODEL S-36PF1E5A×3 OUTDOOR MODEL U-100PE1E8A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 25 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-36PF1E5A×4 / U-125PE1E8A INDOOR MODEL S-36PF1E5A×4 OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 26 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-45PF1E5A×3 / U-125PE1E8A INDOOR MODEL S-45PF1E5A×3 OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 27 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-50PF1E5A×2 / U-100PE1E8A INDOOR MODEL S-50PF1E5A×2 OUTDOOR MODEL U-100PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 28 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-50PF1E5A×3 / U-140PE1E8A INDOOR MODEL S-50PF1E5A×3 OUTDOOR MODEL U-140PE1E8A Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 29 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-60PF1E5A×2 / U-125PE1E8A INDOOR MODEL S-60PF1E5A×2 OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 30 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-71PF1E5A / U-71PE1E8A INDOOR MODEL S-71PF1E5A OUTDOOR MODEL U-71PE1E8A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 7.10 7.10 7.10...
  • Page 31 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-71PF1E5A×2 / U-140PE1E8A INDOOR MODEL S-71PF1E5A×2 OUTDOOR MODEL U-140PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 32 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-100PF1E5A / U-100PE1E8A INDOOR MODEL S-100PF1E5A OUTDOOR MODEL U-100PE1E8A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 33 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-125PF1E5A / U-125PE1E8A INDOOR MODEL S-125PF1E5A OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 34 Single -Type 1-1. Unit Specifi cations 4. Low Silhouette Ducted Type S-140PF1E5A / U-140PE1E8A INDOOR MODEL S-140PF1E5A OUTDOOR MODEL U-140PE1E8A Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 35 Simultaneous (Twin) -Type 1-1. Unit Specifications PEY1 4. Low Silhouette Ducted Type S-36PF1E5A×2 / U-71PEY1E5 INDOOR MODEL S-36PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø...
  • Page 36: Pey1

    Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-50PF1E5A×2 / U-100PEY1E5 INDOOR MODEL S-50PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 37 Single-Type 1-1. Unit Specifications PEY1 4. Low Silhouette Ducted Type S-60PF1E5A / U-60PEY1E5 INDOOR MODEL S-60PF1E5A PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h...
  • Page 38 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-60PF1E5A×2 / U-125PEY1E5 INDOOR MODEL S-60PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø...
  • Page 39 Single-Type 1-1. Unit Specifications PEY1 4. Low Silhouette Ducted Type S-71PF1E5A / U-71PEY1E5 INDOOR MODEL S-71PF1E5A PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h...
  • Page 40 Single -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-100PF1E5A / U-100PEY1E5 INDOOR MODEL S-100PF1E5A PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 1ø...
  • Page 41 Single -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-125PF1E5A / U-125PEY1E5 INDOOR MODEL S-125PF1E5A PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 42 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-50PF1E5A×2 / U-100PEY1E8 INDOOR MODEL S-50PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 43 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-60PF1E5A×2 / U-125PEY1E8 INDOOR MODEL S-60PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø...
  • Page 44 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-71PF1E5A×2 / U-140PEY1E8 INDOOR MODEL S-71PF1E5A×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø...
  • Page 45 Single -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-100PF1E5A / U-100PEY1E8 INDOOR MODEL S-100PF1E5A PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102 ø, Hz 1ø 50Hz 3ø...
  • Page 46 Single -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-125PF1E5A / U-125PEY1E8 INDOOR MODEL S-125PF1E5A PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 47 Single -Type 1-1. Unit Specifi cations PEY1 4. Low Silhouette Ducted Type S-140PF1E5A / U-140PEY1E8 INDOOR MODEL S-140PF1E5A PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 48 1-2. Dimensional Data (A) Indoor Units: S-36PF1E5A, S-45PF1E5A, S-50PF1E5A, S-60PF1E5A, S-71PF1E5A, S-100PF1E5A, S-125PF1E5A, S-140PF1E5A Unit: mm Type 36, 45, 50 450 (Pitch 150 × 3) 60, 71 1,067 1,000 750 (Pitch 150 × 5) 100, 125, 140 1,467 1,400 1,050 (Pitch 150 × 7) 1,192 a) Refrigerant tubing joint (liquid tube) b) Refrigerant tubing joint (gas tube)
  • Page 49 1-2. Dimensional Data (B) Outdoor Unit: U-50PE1E5 U-60PEY1E5 / U-71PEY1E5 (97) Drain port Air intake Air intake Drain port Air discharge (161) Refrigerant tubing joint (liquid tube) Unit: mm (157) Flare connection ø6.35 mm (50) ø9.52 mm (60, 71) Refrigerant tubing joint (gas tube) Flare connection ø12.7 mm (50) ø15.88 mm (60, 71) 1-199...
  • Page 50 1-2. Dimensional Data (B) Outdoor Units: U-60PE1E5A / U-71PE1E5A/ U-100PEY1E5/ U-125PEY1E5 U-71PE1E8A / U-100PEY1E8/ U-125PEY1E8 Unit:mm or more or more 2-U shaped hole Air intake Space for piping,wiring and maintenance Air intake Air discharge 2-18x13 Anchor hole 68.5 Hole (Bottom) Air discharge Air intake Handle...
  • Page 51 1-2. Dimensional Data (B) Outdoor Units: U-100PE1E5A / U-125PE1E5A / U-140PE1E5A U-100PE1E8A / U-125PE1E8A / U-140PE1E8A / U-140PEY1E8 or more or more 2-U shaped hole Air intake Space for piping,wiring and maintenance Air intake Air discharge 2-18x13 Anchor hole 68.5 Hole (Bottom) Air intake...
  • Page 52: (A) Indoor Units

    1-3. Refrigerant Flow Diagram Outdoor Unit: U-50PE1E5 Indoor Unit: Accumulator Compressor Gas line service valve ø12.7 Flare connection High pressure switch Muffler Muffler Heat exchanger 4-way valve Heat exchanger Distributor Strainer Electronic ref. Liquid line control valve service valve ø6.35 Flare connection Strainer Cooling cycle...
  • Page 53 1-3. Refrigerant Flow Diagram Outdoor Units: U-60PE1E5A / U-71PE1E5A Indoor Unit U-71PE1E8A High pressure 4-way switch valve Muffler ø15.88 Outdoor-air Heat Temp Thermistor exchanger Suction Temp Heat exchanger Thermistor Temp Thermistor Heat exchanger Discharge Temp Distributor Thermistor Defrost Temp Thermistor Strainer Distributor ø9.52...
  • Page 54: (B) Outdoor Units

    1-3. Refrigerant Flow Diagram Outdoor Units: U-100PEY1E5 / U-100PEY1E8 : t i Indoor Unit: High pressure 4-way switch valve ø15.88 Outdoor-air Heat Temp Thermistor exchanger Suction Temp Heat exchanger Thermistor Temp Thermistor Discharge Temp Thermistor Heat exchanger Distributor Defrost Temp Thermistor Strainer Distributor...
  • Page 55 1-4. Operationg Range Type PE1 Temperature Indoor air intake temp. Outdoor air intake temp. Maximum 32°C DB / 25°C WB 46°C DB Cooling Minimum 18°C DB / 14°C WB -15°C DB Maximum 30°C DB / − WB 24°C DB/18°C WB Heating Minimum 16°C DB / −...
  • Page 56: Capacity Correction Graph According To Temperature Condition

    1-5. Capacity Correction Graph According to Temperature Condition U-50PE1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 24 °CDB 20 °CDB...
  • Page 57 1-5. Capacity Correction Graph According to Temperature Condition U-60PE1E5A (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 16 °CDB 20 °CDB 22°CWB 19°CWB 24 °CDB...
  • Page 58 1-5. Capacity Correction Graph According to Temperature Condition U-71PE1E5A (For 50 Hz) / U-71PE1E8A (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 16 °CDB 20 °CDB 22°CWB...
  • Page 59 1-5. Capacity Correction Graph According to Temperature Condition U-100PE1E5A (For 50 Hz) / U-100PE1E8A (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 60 1-5. Capacity Correction Graph According to Temperature Condition U-125PE1E5A (For 50 Hz) / U-125PE1E8A (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 61 1-5. Capacity Correction Graph According to Temperature Condition U-140PE1E5A (For 50 Hz) / U-140PE1E8A (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 62 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-60PEY1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) 24 °CDB 20 °CDB 16 °CDB...
  • Page 63 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-71PEY1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 24 °CDB 20 °CDB...
  • Page 64 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-100PEY1E5 (For 50 Hz) / U-100PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 65 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-125PEY1E5 (For 50 Hz) / U-125PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 66: Capacity Correction Graph According To Temperature Condition

    1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-140PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB 16°CWB...
  • Page 67: Noise Criterion Curves

    1-6. Noise Criterion Curves (A) Indoor Units High Low Silhouette Ducted Type : S-36PF1E5A : S-45PF1E5A MODEL MODEL : High 33 dB(A) : High 33 dB(A) SOUND LEVEL SOUND LEVEL 25 dB(A) 25 dB(A) : Under the unit 1.5m CONDITION CONDITION : Under the unit 1.5m SOURCE...
  • Page 68 1-6. Noise Criterion Curves (A) Indoor Units High Low Silhouette Ducted Type : S-100PF1E5A : S-125PF1E5A MODEL MODEL : High 38 dB(A) : High 39 dB(A) SOUND LEVEL SOUND LEVEL 31 dB(A) 32 dB(A) : Under the unit 1.5m CONDITION CONDITION : Under the unit 1.5m SOURCE...
  • Page 69 1-6. Noise Criterion Curves (A) Indoor Units High Ducted Type MODEL : S-36PN1E5A MODEL : S-45PN1E5A S-50PN1E5A SOUND LEVEL SOUND LEVEL : HIGH 40 dB(A) : HIGH 41 dB(A) 35 dB(A) 35 dB(A) CONDITION CONDITION : Under the unit 1.5m : Under the unit 1.5m SOURCE SOURCE...
  • Page 70 1-6. Noise Criterion Curves (B) Outdoor Unit : U-50PE1E5 : U-50PE1E5 MODEL MODEL SOUND LEVEL : Cooling 46 dB(A) SOUND LEVEL : Heating 50 dB(A) : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION : 220-230-240V, 1 phase, 50Hz...
  • Page 71 1-6. Noise Criterion Curves (B) Outdoor Unit : U-60PE1E5A : U-60PE1E5A MODEL MODEL SOUND LEVEL : Cooling 48 dB(A) SOUND LEVEL : Heating 50 dB(A) : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION : 220-230-240V, 1 phase, 50Hz...
  • Page 72 1-6. Noise Criterion Curves (B) Outdoor Unit : U-100PE1E5A, U-100PE1E8A : U-100PE1E5A, U-100PE1E8A MODEL MODEL SOUND LEVEL : Cooling 52 dB(A) SOUND LEVEL : Heating 52 dB(A) : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION 1 phase model...
  • Page 73 1-6. Noise Criterion Curves (B) Outdoor Unit : U-140PE1E5A, U-140PE1E8A : U-140PE1E5A, U-140PE1E8A MODEL MODEL SOUND LEVEL : Cooling 54 dB(A) SOUND LEVEL : Heating 55 dB(A) : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION 1 phase model...
  • Page 74 1-6. Noise Criterion Curves (B) Outdoor Unit MODEL : U-60PEY1E5 MODEL : U-60PEY1E5 : Cooling 46 dB(A) : Heating 50 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 75 1-6. Noise Criterion Curves (B) Outdoor Unit : U-100PEY1E5, U-100PEY1E8 : U-100PEY1E5, U-100PEY1E8 MODEL MODEL SOUND LEVEL : Cooling 54 dB(A) SOUND LEVEL : Heating 54 dB(A) : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION 1 phase model...
  • Page 76 1-6. Noise Criterion Curves (B) Outdoor Unit : U-140PEY1E8 MODEL : U-140PEY1E8 MODEL : Cooling 54 dB(A) SOUND LEVEL SOUND LEVEL : Heating 53 dB(A) CONDITION : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION SOURCE : 380-400-415V, 3 phase, 50Hz...
  • Page 77: Fresh Air Intake

    1-9. Fresh Air Intake 1-9-1. Precautions Regarding External Air Intake (1) Ventilation Load Ensure that the design of the air-conditioner takes air-conditioning loads into consideration when external air intake is involved. (2) Restrictions on External Air Intake Ensure that the design conforms to the restrictions on air intake volume stipulated in accordance with the model of the indoor unit and the intake method.
  • Page 78 1-9-2. External Air Intake Volume & Resistance Within Unit / Operation Noise Characteristics (continued) Low Silhouette Ducted (F2 Type) 1-9-2-4. In a Case of External Air Intake to Unit Directly (Using external air intake cylindrical flange) Operation noise Resistance within the unit (External air intake only) (High speed wind) External air intake cylindrical flange...
  • Page 79: Electrical Wiring

    1-10. Electrical Wiring General Precautions on Wiring Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. Provide a power outlet to be used exclusively for each unit and a circuit breaker for overcurrent protection should be provided in the exclusive line.
  • Page 80 Wiring System Diagrams * 3-phase model connections Indoor unit (No. 1) Power supply Outdoor unit (3-phase) 220/230/240V ~50Hz INV unit Power supply Ground Remote 380/400/415V, 3 N~, 50Hz controller Ground Ground Ground Indoor unit * Single-phase model connections (No. 2) Power supply Ground Outdoor unit (single-phase)
  • Page 81: Outdoor Unit

    CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 82 How to connect wiring to the terminal For stranded wiring Cut the wire end with cutting pliers, Stranded wire Special Screw then strip the insulation to expose washer the stranded wiring about 10 mm and Ring Ring pressure Screw and tightly twist the wire ends.
  • Page 83 Wiring samples K1 type T2 type Remote control wiring and inter-unit control wiring inlet port Functional ground screw (External Electronic * Insert the remote control wiring and inter- Expansion Valve Kit and Schedule Timer)* unit control wiring into the electrical Protective ground screw component box from the inlet port as Fixture screw for resin cover...
  • Page 84: Capacity Table

    :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 85 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 86 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 87 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 88 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 89 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 90 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 91: Heating Capacity Performance Data

    1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Sihouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.87 1.92...
  • Page 92 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88...
  • Page 93 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.80 1.83...
  • Page 94 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.86 1.95...
  • Page 95 3. ELECTRICAL DATA 3-1. Indoor Units (Electric Wiring Diagram Schematic Diagram) ........3-2 4-Way Cassette Type ..........................3-2 4-Way Cassette 60 × 60 Type ......................... 3-3 Ceiling Type ............................3-4 Wall Mounted Type ..........................3-7 Low Silhouette Ducted Type ........................3-8 Ducted Type ............................
  • Page 96: Indoor Units (Electric Wiring Diagram, Schematic Diagram)

    3-1. Indoor Units Low Silhouette Ducted Type S-36PF1E5A / S-45PF1E5A / S-50PF1E5A / S-60PF1E5A / S-71PF1E5A               S-100PF1E5A / S-125PF1E5A / S-140PF1E5A Electric Wiring Diagram...
  • Page 97 3-2. Outdoor Units Single-phase U-50PE1E5 3-11...
  • Page 98 3-2. Outdoor Units Single-phase U-50PE1E5 3-12...
  • Page 99: Outdoor Units (Electric Wiring Diagram)

    3-2. Outdoor Units Single-phase U-60PE1E5A / U-71PE1E5A 3-13...
  • Page 100 3-2. Outdoor Units Single-phase U-100PE1E5A / U-125PE1E5A / U-140PE1E5A 3-14...
  • Page 101 3-2. Outdoor Units Single-phase U-60PEY1E5 / U-71PEY1E5 3-15...
  • Page 102 3-2. Outdoor Units Single-phase U-60PEY1E5 / U-71PEY1E5 3-16...
  • Page 103 3-2. Outdoor Units Single-phase U-100PEY1E5 / U-125PEY1E5 3-17...
  • Page 104 3-2. Outdoor Units 3-phase U-71PE1E8A 3-18...
  • Page 105 3-2. Outdoor Units 3-phase U-100PEY1E8 / U-125PEY1E8 3-19...
  • Page 106 3-2. Outdoor Units 3-phase U-100PE1E8A / U-125PE1E8A / U-140PE1E8A / U-140PEY1E8 3-20...