SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
catches up. The current limiting feature of the
control still functions in the Manual Mode so
each side can be fully retracted until it stops.
CAUTION
Never let one side get more than 2 inches
(50 mm) ahead of the other while
retracting.
Once the room has been retracted, the control
will return to the automatic mode after 60
seconds.
In the event of a total system failure where
Manual Mode cannot be used, two crank handles
may be used to retract or extend the room. See

Slideout Emergency Retraction - Electric

elsewhere in this section.
Problems Extending the Room
Set the Park Brake if the Engage Park Brake
light flashes while pressing the Extend (OUT)
button.
• Light will flash if
park brake not set
• Low Voltage
Indicator
Slideout Touchpad
(Located near monitor panel)
-Typical View
If an error is detected on your slide system, the
LED light on the control panel will blink an error
code. If an error code appears, see the
manufacturer's user guide in your InfoCase to
determine the problem. The error code must be
10-6
• Light will flash fault
code if system
malfunctions
cleared prior to operating the room. To clear the
error, perform the following steps (one at a time)
to reset the system:
If none of the "Battery Voltage or Circuit
Breaker Problems" troubleshooting
recommendations reset the system, remove
the touchpad from the monitor panel (a
screwdriver will be needed) and press and
hold the RESET button ("Set Stops/Clear
Fault") located on the back of the touchpad for
5 seconds. The slideout is now ready to be
extended. Press OUT on the touchpad to
extend the room.
If touchpad was removed, reinstall to the wall.
Take your vehicle to an authorized service
center for repair.
Further Information
See the slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION - ELECTRIC
-If Equipped
If the slideout mechanism is malfunctioning
and the room will not retract using the interior
control switch, you may need to access the
motor/gear assembly and manually crank the
room in to the travel position.
Each front slideout room has two motor/
gearbox units, which are located beneath each of
of the slideout room rails.
Crank-In Procedure
Disengage the motor brakes, which appear as
a flat "square" protrusion on the protective
boot at the end of each motor. Move the brake
lever slightly – about 1/8 turn counter-
clockwise (to left when facing end of motor).
Disconnect the motor power lead from the
wiring harness (repeat for motor at other end
of room).