Frontier LP7500 Service Manual page 862

Qss-37 series
Table of Contents

Advertisement

Distributed by: minilablaser.com
LED No.
LED20
DC+5 V power supply check
*1. Table (You can check whether the pump is working by ON/OFF of LED16, 17 and 18.)
CD−W
Refilling water
pump
LED16
On
LED17
Off
LED18
Off
Cleaning pump
LED16
LED17
LED18
Test point No.
TP1
AC+24 V voltage measurement
TP2
AC+24 V voltage measurement
TP3
DC+5 V power supply measurement
TP4
DC+24 V voltage measurement
TP5
Ground
TP6
Ground
Fuse No.
F14
F15
F16
Purpose
BF−W
Refilling water
pump
Off
On
Off
On
On
On
Purpose
Rating
T6.3 A/125 V
T6.3 A/125 V
T3.15 A/125 V
66210
Explanation of PCBs (Processor section)
STB1−W
STB2−W
Refilling water
Refilling water
pump
pump
On
Off
On
Off
Off
On
Measurement with voltmeter
Possible
Possible
Possible
Possible
Possible
Possible
Purpose
DC+24 V power voltage protection
DC+24 V power voltage protection
AC+24 V power supply protection
66210
Status
On when the power supply is turned on.
STB3−W
STB4−W
Refilling water
Refilling water
pump
On
Off
On
Remarks
Remarks
pump
Off
On
On
3/3

Hide quick links:

Advertisement

Table of Contents
loading