Standard Replenishment Amount Setting[F]

! ! ! ! Display
Bringing up the display
Maintenance: 2260 → Extension → Processor Settings → Standard Replenishment Amount Setting
! ! ! ! Explanation
N
OTE
• Enter the service personnel password (2260) to set the standard replenishment amount of P1R, P2RA and P2RB.
! ! ! ! Standard Replenishment Amount Setting (Input range: 0.1 to 500.0 mL/m2)
The standard replenishment amount of P1R, P2RA, P2RB and PSR can be specified on the Standard Replenishment Amount Setting.
• In the replenishment package or process specification change, change the standard replenishment amount only when the instruction
for changing the standard replenishment amount arrives from the manufacturer.
• Do not change the standard replenishment amount without the instruction from the manufacturer.
! ! ! ! Replenishment rate by magazine (Initial value: 1.0 for P1R/P2RA/P2RB/PSR) (Input range: from 1.0 to
2.0)
The standard replenishment amount of P1R/P2RA/P2RB, PSR can be specified for each Width, Paper Surface and Magazine ID.
• If using professional paper, change Replenishment rate by magazine only when the instruction is given by the manufacturer.
• Do not change the Replenishment rate by magazine without the instruction from the manufacturer.
• Example: Basic replenishment amounts when Replenishment rate by magazine of P1R/P2RA/P2RB is set to 1.2 for a paper
magazine whose Width is 127 mm and Paper Surface is (1)
Processing
solution
replenishment
amount
P1R
108.0mL/m2
P2RA
108.0mL/m2
P2RB
108.0mL/m2
PSR
248.0mL/m2
M5466-00
Basic
Replenishment rate by
magazine
1.2
1.2
1.2
1
33002
Basic replenishment amount after Replenishment rate
by magazine is changed
33002
Processor Settings
129.6mL/m2
129.6mL/m2
129.6mL/m2
248.0mL/m2