Frontier LP7500 Service Manual page 102

Qss-37 series
Table of Contents

Advertisement

Distributed by: minilablaser.com
2.
Execute Test Operation for the Paper Stop Position Correction via F: Functions of Paper Advance
Unit Correction.
Confirm the dimension between the front ends of arm unit 2 and paper is from 3.0±0.5 mm.
Paper advance unit 1
Arm unit 2
3.
If an adjustment is necessary, perform Paper Advance Unit Correction.
36010
26510
Paper
3.0±0.5 mm
26510
G068452
Paper advance unit 1
4/4