Frontier LP7500 Service Manual page 334

Qss-37 series
Table of Contents

Advertisement

Distributed by: minilablaser.com
Example: If the diagnosis result is normal (FRONTIER-Printer: Ver. 3.0 or later, QSS-Printer: Ver. 5.0
or later)
Laser Self-Diagnostic
4.
Right Source Status (R) and Right Source Status (B) are abnormal
Confirm graph (R) and graph (B).
LD current graph (normal)
Diagnosis example
Graph (1),
Graph (2)
If the graph of the LD current is not showing a straight line but a polygonal line that touches the upper bound or keeps touching it, it
is assumed that the laser unit LD is deteriorated.
Countermeasure: replace the laser unit.
Graph (3)
If the graph of the LD current is showing a horizontal line that lies near 0 mV level, connection failure in the laser control PCB
connector (coaxial cable (R)) or failure in the laser control PCB can be suspected.
Diagnosis example (when problem lies in G laser)
5.
Synchronous Detection Setting Value G is abnormal
• Confirm that there is no connection failure in wiring between the laser control PCB and the laser unit.
• Confirm that there is no connection failure in wiring between the laser control PCB and the G-AOM driver.
6.
Perform Laser Self-Diagnostic (AUTO) again, and if it still recurs, replace the G-AOM driver.
1. Perform Laser Self-Diagnostic (AUTO) again.
Synchronous Detection Setting Value G is abnormal
• There is a possibility of failure in the laser unit.
1. Countermeasure 1: reattach the G-AOM driver then replace the laser unit.
2. Countermeasure 2: diagnose again by Laser Self-Diagnostic (AUTO) .
35951
LD current graph (abnormal)
Graph (1)
35951
Laser Self-Diagnostic (graph (R))
Graph (2)
Self-diagnostic
Graph (3)
2/3