16. Soft Switch Set (bizhub 160f/bizhub 161f only)
16.8.2

SOFT SWITCH: #02

Bit
Designation
No.
8
Time between phase C
to phase D signal in
7
V.17
Example:
Image --> EOP
6
Header TX selection
open to user
5
Reserved
4
Reserved
3
Transmit RTN signal
level criteria
2
1
Sent N.G page
• Bit 1
:If this bit is set to '0', N.G indicates our side detected RTN signal from other
end. In this case machine can re-send the same page up to three or just one
time, and this use for G3 mode only.
• Bit 2 to 3 :In G3 mode, if error line for each page meets the criteria setting, receiving
machine will send RTN signal, in this case, some machine will re-send the
same page again. The retry times depend on transmission side.
• Bit 6
:If this bit is set to '0', the header select function can not be changed by user,
only changeable by serviceman in service mode.
184
Function
RX Insensitivity
70 ms 120 ms 180 ms
Bit 8
0
Bit 7
0
0: No
1: Yes
Reserved
Reserved
Percentage of
10 %
error line
Bit 3
0
Bit 2
0
0: Send N.G page and up to 3 times for that page
1: Not re-send that N.G page for G3 mode
Field Service Ver. 1.0 Apr. 2005
60 ms
0
1
1
1
0
1
15 %
20 %
25 %
0
1
1
1
0
1
Initial
Setting
Bit
HEX
0
2
0
1
0
0
0
0
0
0