Testing A Door / Window Detector Independently; The Control Panel - Response SL5 Installation & Operating Manual

36 zone wireless security system
Table of Contents

Advertisement

6.
Switch SW3 is used to enable / disable the
internal / external wired magnetic contact.
Location of
Key-hole Screw
(underside)
Terminal Block for
Additional Wired
Magnetic Contact
Tamper
Switch
Position of SW3
INT.
INT./EXT.
7.
Set the
Door / Window Detector by setting the
position of the switch (SW3).
INT.
INT./EXT.
Switch SW3
INT. Position
If setting to the INT. position, only the internal
contact will be active. When two contacts are in
use for internal and external connection
simultaneously (INT./EXT. position), only one
activation will be counted if one of the contacts is
opened. If one contact is left open and the other
closed contact is opened then an activation will
be counted.
If using external contacts wired to the Detector,
set to the INT./EXT. position.
IMPORTANT:
If
set to the INT. position for the Detector to
operate correctly.
8.
Refit the battery cover.
8mm
11mm
Switch
SW3
INT.
INT./EXT.
Hole for
Mounting
Screw
Function
Internal Contact ON
Internal and External
Contacts ON
INT.
INT./EXT.
Switch SW3
INT./EXT. Position
not using external contacts,
TESTING
A MAGNETIC DOOR / WINDOW
DETECTOR INDEPENDENTLY
9.
Remove battery cover to activate the tamper switch.
As the button is released the LED indicator will
illuminate for approximately 1 second to show
that the tamper switch has been triggered and a
signal is being transmitted.
10. Open the
door / window to remove the Magnet
from the Detector.
As the Magnet is moved away from the Detector
the LED indicator will illuminate for
approximately 1 second to show that the
Detector has been triggered and a signal is
being transmitted.
Note: It does not
illuminates as the magnet is brought towards
the detector.
LINKING
A MAGNETIC DOOR / WINDOW
DETECTOR TO THE CONTROL PANEL
1.
Remove the battery cover after installing and
configuring it.
2.
With the system in Standby
,
?
Press
Installer Access Code
to enter Program Mode.
3.
Scroll through the programming menu until
'3.
ZONE SETUP'
4.
Enter the
zone number to be configured (1 - 36)
and press
.
ENTER
Note: Zones
33 - 36 the wired zones are the
same except there is no learn menu option as
these are wired.
5.
To learn a new detector ID code and link it to the
selected zone press
The panel will now listen for a valid signal from
a new detector to link to the zone.
The Panel will remain in Learn Mode for 30s.
If a valid signal is not received from a new
detector within 30s it will automatically exit
Learn Mode and return to the top of level 3.1
matter if the LED indicator
,
?
?
?
ENTER
is
displayed and press
3
.
.
ENTER
19