INSTALLING AND CONFIGURING THE
PIR DETECTORS
Rear Cover
Fixing
Screw
1.
Undo and
remove the fixing screw from the
bottom edge of the PIR Detector, (keep the
screw safe for later). Carefully pull the bottom
edge of the detector away from the rear cover
and then slide down to release the top clips.
2.
Carefully drill out the required mounting holes in
the rear cover using a 3mm drill according to
whether the unit is being mounted in a corner or
against a flat wall.
3.
Using the
rear cover as a template, mark the
positions of the fixing holes on the wall.
Flat Wall
Mounting
Corner Wall
Mounting
Rear Cover
Fixing
Screw
SW1 (Test Mode)
SW2 (Tamper)
SW3 (Sensitivity)
4.
Fix the
rear cover to the wall using the two
18mm No.4 screws and 22mm wall plugs,
(a 5mm hole will be required for the wall plugs).
Do not over-tighten the screws as this may
distort or damage the cover.
Note:
The wall plugs supplied with the product
are not suitable for plasterboard walls, if
mounting the Detector onto plasterboard use
appropriate wall plugs.
5.
To select the required sensitivity, set switch SW3
as follows:
UP
HIGH sensitivity
DOWN
LOW sensitivity
Sensitivity
Hi
Low
SW3 up
High Sensitivity
Note:
The recommended setting is HIGH.
However, in cases of extreme environmental
problems or if unexplained false alarms are
experienced, it may be necessary to set the
sensitivity to LOW. Setting the device to LOW
sensitivity will require a greater amount of
movement in order to trigger the device.
6.
Connect the PP3
clip. The LED behind the lens will rapidly flash
for approximately 2-3 minutes until the PIR has
stabilised. The LED will then stop flashing and
turn OFF .
TESTING
A PIR DETECTOR
INDEPENDENTLY
7.
Ensure that the LED indicator has stopped
flashing rapidly.
8.
The 'Test Mode' button (SW1) is used to put
the PIR Detector into Walk Test
overrides the 2 minute sleep period and allows
the operation of the detector to be checked
during installation. Press and hold the button
for 2 seconds to activate Test Mode for a fixed
5 minute after which it will automatically revert
to normal operation.
Sensitivity
Hi
Low
SW3 down
Low Sensitivity
Alkaline battery to the battery
Mode,
which
15