Installing And Configuring The Door / Window Detectors - Response SL5 Installation & Operating Manual

36 zone wireless security system
Table of Contents

Advertisement

Do not fix the Detector onto or
metalwork (i.e. radiators, water pipes, etc) as this
could affect the radio range of the device.
On
PVC door / window frames, it may be necessary to
space the Detector and Magnet away from the metal
surface using a plastic or wooden spacer to achieve
the necessary radio range.
INSTALLING AND CONFIGURING THE
MAGNETIC DOOR / WINDOW DETECTORS
The Detector and Magnet should be mounted
together along the opening edge of the window/door
opposite the hinges. Ensure that the parallel gap
between the Magnet and Detector is less than 10mm
and that the arrow on the magnet is aligned with the
mark on the detector.
1.
Remove the battery cover by sliding and lifting it
off. (DO NOT use a screwdriver to lever it off).
Raised Head Screw,
Key-hole Slot Fixing
Double Sided Tape
OR Screw Fixing
2.
Slide the
two batteries supplied into the battery
holder, ensuring that the
each battery as it is installed.
TWO
Fit
Batteries
3.
If
necessary, refit the battery holder into the
detector ensuring that the spring clip connectors
slide onto either side of the circuit board.
The Detector should be mounted on the fixed part
of the frame and the magnet on the opening part.
The Detector and Magnet should be mounted
using the double sided adhesive pads or screws
provided.
18
very close to
Slide Open and Lift Off
Do Not Use A Screwdriver
Small Counter-sunk
Screw Fixing
+
side is
uppermost on
Battery
Connector
Tilt and Remove
Battery Holder
and Insert
Two Batteries
Note: If
mounting the device using the adhesive
pads, ensure that the mounting surfaces are
clean and dry before mounting.
Detector
Magnet
4.
If
fixing the detector with screws first remove
the battery holder by carefully tilting up the
end and pulling away from the printed circuit
board (PCB).
The top of the Detector is secured by hanging
the keyhole slot over the head of the 10mm pan
head screw. The bottom of the Detector is
secured using the 12mm counter-sunk head
screw fitted within the battery compartment.
Carefully drill out the centre of the fixing screw
hole in the battery compartment using a 3mm
drill. Fit the Magnet using the two 15mm fixing
screws. Do not over- tighten the screws as this
may distort or damage the casing.
5.
If
an additional wired Magnetic Contact is
required, this should be wired to the terminal
block provided in the battery compartment.
The wired contact should be connected using
a maximum length of 1.5 metres of any of
the following:
– 6 core alarm cable
– 2 core bell wire (6 x 0.2mm minimum)
– 2 core 24AWG wire
A cable entry cut-out is provided beside the
terminal block in the battery cover.
Alternative
Mountings

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents